The Intel

®

 RAID Controller SRCSASJV is a high-performance intelligent PCI-Express* 

SAS/SATA RAID controller that offers reliability, high performance, and fault-tolerant 

disk subsystem management. This is a RAID solution that meets the internal and external 

storage needs of workgroup, department, or enterprise systems that use cost-effective 

SATA or high performance SAS media. 

As a third generation PCI Express storage controller, the Intel

®

 RAID Controller 

SRCSASJV addresses the demand for increased data throughput and scalability 

requirements across entry level and midrange and enterprise server platforms. 

The controller can be connected to up to eight drives directly and allows the use of 

expanders to connect to additional drives. See the ANSI SAS standard, version 1.0 

specification for more information about the use of expanders.

SATA and SAS are serial, point-to-point, device interfaces that use simplified cabling, 

smaller connectors, lower pin counts, and lower power requirements than parallel SCSI. 

An optional Intel

®

 RAID backup battery unit can provide cached data protection for the 

RAID controller, even during system failures.

Benefits of SAS

SAS is a serial, point-to-point, enterprise-level device interface that leverages the proven 

SCSI protocol set. SAS is a convergence of the advantages of SATA, SCSI, and FC, and is 

the future mainstay of the enterprise and high-end workstation storage markets. SAS 

offers a higher bandwidth per pin than parallel SCSI and improves signal and data 

integrity. 

The SAS interface uses the proven SCSI command set to ensure reliable data transfers, 

while providing the connectivity and flexibility of point-to-point serial data transfers. The 

serial transmission of SCSI commands eliminates clock skew challenges. The SAS 

interface provides improved performance, simplified cabling, smaller connectors, lower 

pin count, and lower power requirements than parallel SCSI. 

SAS controllers leverage a common electrical and physical connection interface that is 

compatible with Serial ATA technology. The SAS and SATA protocols use a thin, 7-wire 

connector instead of the 68-wire SCSI cable or 40-wire ATA cable. The SAS/SATA 

connector and cable are easier to manipulate, connect to smaller devices, and do not 

inhibit airflow. The point-to-point SATA architecture eliminates difficulties created by the 

legacy ATA master-slave architecture, while maintaining compatibility with existing ATA 

firmware.

Содержание SRCSASJV

Страница 1: ...Intel RAID Controller SRCSASJV Hardware User s Guide Intel Order Number E16747 001...

Страница 2: ...CTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not i...

Страница 3: ...who benefit from this book are Engineers who are designing a Intel RAID Controller SRCSASJV storage adapter into a system Anyone installing a Intel RAID Controller SRCSASJV storage adapter in their R...

Страница 4: ...iv Intel RAID Controller SRCSASJV Hardware User s Guide...

Страница 5: ...ation 6 Requirements 6 Install the RAID Controller 6 Configure the RAID Controller 9 Replacing a Controller Resolving a Config Mismatch 9 Chapter 3 Intel RAID Controller SRCSASJV Characteristics 10 Te...

Страница 6: ...tion for the RAID controller even during system failures Benefits of SAS SAS is a serial point to point enterprise level device interface that leverages the proven SCSI protocol set SAS is a convergen...

Страница 7: ...SATA II Protocol Communication with other SATA II devices Serial Management Protocol SMP Topology management information sharing with expanders Serial Tunneling Protocol STP support for SATA II throu...

Страница 8: ...out of band SES2 Enclosure management support Drive coercion auto resizing to match existing disks Auto detection of failed drives with transparent rebuild There must be disk activity I O to the drive...

Страница 9: ...disk if data is not in the cache Direct I O Reads data directly from disk not cache Redundancy through Configuration stored in nonvolatile RAM and on the drives COD Hot swap support Optional battery b...

Страница 10: ...5 to RAID 0 RAID 6 to RAID 0 With OCE migrations supported are RAID 0 to RAID 1 RAID 0 to RAID 5 RAID 1 to RAID 5 Beep Codes Short beep 1 second on 1 second off Array is degraded but no data lost Long...

Страница 11: ...stall the RAID Controller 1 Turn off the power to the system and all drives enclosures and system components Remove the power cord s 2 Follow the instructions that came with your server system to remo...

Страница 12: ...er an internal cable provided or an external SFF8088 cable not provided to the appropriate lower connector If you are using more than four drives without using an expander backplane connect the second...

Страница 13: ...JV Hardware User s Guide 8 Figure 3 Connecting Cables between the RAID Controller and Drives Backplane 6 Install the server system cover and connect the power cords See your server system documentatio...

Страница 14: ...the Intel RAID Controller SRCSASJV Quick Start User s Guide and the Software User s Guide for instructions to configure the RAID controller and to install the operating system drivers Replacing a Cont...

Страница 15: ...Factory use only J2 I2C header 3 pin Enclosure management support usually for non expander hot swap backplane J8 Mode selector 2 pin Default is for no jumper J9 Cache write pending LED 2 pin Provides...

Страница 16: ...SFF8088 Physical and virtual drive support 2x4 ports total 240 drives per controller 64 virtual drives per controller 240 hot spares per controller global and or dedicated Cache DDR2 667 MHz SDRAM opt...

Страница 17: ...rough Read Ahead Adaptive Read Ahead NonRead Ahead Cache I O or Direct I O Self Monitoring Analysis and Reporting Technology SMART support Detects up to 70 of predictable disk drive failures and monit...

Страница 18: ...rd is marked with the supplier name or trademark type and UL flammability rating For the boards installed in a PCI bus slot all voltages are lower than the SELV 42 4 V limit PCI 12 V PCI 3 3 Aux PCI 3...

Страница 19: ...Intel RAID Controller SRCSASJV Hardware User s Guide 14...

Страница 20: ...se drive roaming 1 Turn off the power to the system and all drives enclosures and system components Remove the power cord s 2 Follow the instructions that came with your server system to remove the se...

Страница 21: ...em and all drives enclosures and system components Remove the power cord s 3 Follow the instructions that came with your server system to remove the server cover 4 Disconnect the cables from the drive...

Страница 22: ...m from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on your computer system s cables and t...

Страница 23: ...t static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal surfac...

Страница 24: ...nnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of...

Страница 25: ...lter f r Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie...

Страница 26: ...dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie...

Страница 27: ...eliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vou...

Страница 28: ...rruptor activado desactivado en el panel frontal no desconecta la corriente alterna del sistema Para desconectarla deber desenchufar todos los cables de corriente alterna de la pared o desconectar la...

Страница 29: ...pruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extra dos anteriormente tens ndolos firmemente...

Страница 30: ...el sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sistema...

Страница 31: ...ance Class B FCC ICES 003 USA Canada CISPR 22 International EN55022 Europe EN55024 Europe CE EMC Directive 89 336 EEC Europe VCCI Japan AS NZS 3548 Australia New Zealand BSMI CNS13438 Taiwan RRL MIC N...

Страница 32: ...he FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including inte...

Страница 33: ...de reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wit...

Страница 34: ...al apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites bruits...

Отзывы: