Intel® RAID Controller SRCS16
17
Chapter 2
Hardware Installation
This chapter describes the procedures for installing the . It contains the following sections:
•
Section 2.1, “Requirements,” page 17
•
Section 2.2, “Installation,” page 17
•
Section 2.3, “After You Have Installed the RAID Controller,” page 20
2.1
Requirements
The following items are required to install a Intel® RAID Controller SRCS16:
•
An Intel® RAID Controller SRCS16 and operating system driver
•
A host computer with an available 32- or 64-bit, 3.3 V PCI expansion slot
•
The Resource CD
•
The necessary internal SATA cables
•
SATA hard disk drives and cables
Intel strongly recommends using an uninterruptible power supply (UPS).
2.2
Installation
This section provides detailed instructions for installing a RAID Controller SRCS16.
The following steps provide detailed installation instructions.
1) Unpack the RAID Controller SRCS16 and inspect it for damage.
Unpack and install the RAID controller in a static-free environment. Remove the RAID
controller from the anti-static bag and inspect it for damage. Contact your Intel support
representative if the RAID controller appears damaged.
2) Power down the system.
Turn off the computer and physically remove the power cord from the back of the power
supply. Remove the cover from the computer chassis. Disconnect the system from any
networks.
3) Configure the jumpers on the RAID Controller SRCS16.
Configure the jumper settings on the RAID controller. Chapter 3, “Intel® RAID
Controller SRCS16 Technical Reference,” provides the jumper definitions and locations.