Intel® Server System SR9000MK4U Operating System Installation Guide
7
3.2
Installation with USB key
1. Attach the USB key that contains the LSI* SAS drivers to a front USB port.
2. Attach the SAS hard drive to the left drive bay.
3. Insert the Intel
®
Server System SR9000MK4U Resource CD.
4. Power on the server.
5. In the EFI Boot Manager select EFI Shell [Built in] and press <Enter>.
6. Use the map command to make sure the hard drive, USB key, and CD-ROM drive are
visible. If any of these devices is missing from the Device Mapping table check the
physical connections and do this in the EFI Shell:
-
Type
:
reconnect –r
-
Type:
map –r
7. In the Resource CD go to \
Utilities\ramdrive\
8. Type
load ramdrive.efi
9. Type
map –r
10. The ramdrive should be visible on the Device Mapping table. The ramdrive name begins
with “VenMsg”.
Figure 5. System Block for ramdrive.efi
Содержание SR9000MK4U - Server System - 0 MB RAM
Страница 4: ......