![Intel SR6850HW4 - Server Platform - 0 MB RAM Скачать руководство пользователя страница 190](http://html1.mh-extra.com/html/intel/sr6850hw4-server-platform-0-mb-ram/sr6850hw4-server-platform-0-mb-ram_product-manual_2072153190.webp)
190
8 Servicing the RAID on Motherboard (ROMB)
Components
Installing and Removing the Intel
®
RAID Activation
Key
Installing the Intel
®
RAID Activation Key
The optional Intel
®
RAID Activation Key provides access to the RAID functionality on the main
board.
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “Removing the Top Cover”, page 144.
5.
Remove the memory board air baffle or the memory board from Slot C. For instructions, see
“
6.
If a PCI card is in Slot 7, remove it to expose the Intel
®
RAID Activation Key holder. For
instructions on removing a PCI card, see “
Removing a Non-Hot-Plug PCI Card
7.
Remove the new Intel
®
RAID Activation Key from its package
8.
Insert the Activation Key into the socket on the main board and push it into the socket until it is
below the two retaining clips. See letter “C” in Figure 99.
NOTE
Letters “A” and “B” in Figure 99 show the installation of the RAID DIMM.
The RAID DIMM is also required to activate ROMB. For instructions on
installing the RAID DIMM, see “
Installing the RAID DDR2-400 DIMM
”.