165
Cold Removal of Memory Board
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “
5.
Press the latch on the handle (letter “A” in Figure 79) and lift the memory board handle (letter
“B” in Figure 79).
6.
Pull up on the memory board handle to lift the Memory board from the server. See letter “C” in
Figure 79.
7.
Install DIMMs, then reinstall the memory board, or install a memory board air baffle:
-
For instructions to install DIMMs, see “
-
For instructions to install the memory board air baffle, see “
8.
Re-install the top cover. For instructions, see “
Cold Insertion of a Memory Board
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the system.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “
5.
Install DIMMs onto the memory board. For instructions, see “
”.
6.
Remove a memory board air baffle from the server. For instructions, see “Removing Memory
Board Air Baffle”, page 160.
7.
Ensure the handle on the memory board is in the open / up position.
8.
Align the ends in the card guides and slide the memory board into the memory board slot. See
letter “A” in Figure 80.
9.
Push the handle down into the fully-locked position. See letter “B” in Figure 80.
10.
Re-install the top cover. For instructions, see “
”.