Installing the Processor Cache VRM Converter
1.
Observe the safety precautions, warnings, and cautions described in “
2.
Turn off all peripheral devices connected to the server.
3.
Power down the system and unplug both AC power cords.
4.
Remove the top cover. For instructions, see “Removing the Top Cover”, page 144.
5.
Remove the processor air baffle. For instructions, see “
Removing the Processor Air Baffle
6.
Open the two levers on the VRM converter socket. See letter “A” in Figure 97.
7.
Push the processor cache VRM converter firmly into the socket. See letter “B” in the figure.
8.
Make sure the levers close securely. See letter “C” in the figure.
9.
Install the processor air baffle. For instructions, see “
Installing the Processor Air Baffle
”, page
10.
Re-install the top cover. For instructions, see “
TP01536
A
C
B
Figure 97. Installing a Processor Cache VRM Converter