52
Intel
®
Server System SR2612UR Service Guide
Removing the Backplane Board
Observe ESD precautions when servicing this unit. At a minimum, use an ESD grounded
wrist strap when handling electrical components. Where possible utilize a grounded ESD
mat to place drives and components on. For more information, refer to
.
1. Power down the enclosure and remove the power cord(s).
2. Remove all disk drives. Note their slot location in the enclosure.
3. Remove the top cover from the enclosure by loosening the captive screw with a
Phillips screwdriver on the right-rear of the enclosure.
4. Slide the top cover back and lift it from the enclosure.
5. Remove the main power connector from the backplane as shown in Figure 46.
Figure 46. Removing the Main Power Connector from the Backplane
6. Remove the logic cable connector from the backplane as shown in Figure 47
Figure 47. Removing the Logic Cable Connector from the Backplane
7. Remove the midplane from the enclosure as detailed in the User Guide appendix.
(Remove the I/O SAS cable and the two (2) screws holding the midplane in place,
then carefully disconnect the midplane from the backplane.)
Содержание SR2612UR - Server System - 0 MB RAM
Страница 14: ...xiv Intel Server System SR2612UR Service Guide ...
Страница 27: ...Intel Server System SR2612UR Service Guide 13 Figure 8 Intel Server System SR2612UR Configuration Diagram ...
Страница 98: ...84 Intel Server System SR2612UR Service Guide ...
Страница 102: ...88 Intel Server System SR2612UR Service Guide ...
Страница 104: ...90 Intel Server System SR2612UR Service Guide ...
Страница 136: ...122 Intel Server System SR2612UR Service Guide ...
Страница 158: ...144 Intel Server System SR2612UR Service Guide ...
Страница 159: ...Intel Server System SR2612UR Service Guide 145 ...
Страница 160: ...146 Intel Server System SR2612UR Service Guide ...
Страница 161: ...Intel Server System SR2612UR Service Guide 147 ...
Страница 162: ...148 Intel Server System SR2612UR Service Guide ...