![Intel SBCEGBESW1 Скачать руководство пользователя страница 411](http://html1.mh-extra.com/html/intel/sbcegbesw1/sbcegbesw1_manual_2073124411.webp)
802.1x Commands
Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
395
show dot1x users
The
show dot1x users
Privileged EXEC mode command displays active 802.1x
authenticated users for the device.
Syntax
show dot1x users
[
username
username
]
Parameters
•
username —
Supplicant
username (Range: 1-160 characters)
Username
The username representing the identity of the Supplicant. This field shows the
username in case the port control is auto. If the port is Authorized, it shows the
username of the current user. If the port is unauthorized it shows the last user
that was authenticated successfully.
Quiet period
The number of seconds that the device remains in the quiet state following a
failed authentication exchange (for example, the client provided an invalid
password).
Tx period
The number of seconds that the device waits for a response to an Extensible
Authentication Protocol (EAP)-request/identity frame from the client before
resending the request.
Max req
The maximum number of times that the device sends an Extensible
Authentication Protocol (EAP)-request frame (assuming that no response is
received) to the client before restarting the authentication process.
Supplicant timeout
Time in seconds the switch waits for a response to an EAP-request frame from
the client before resending the request.
Server timeout
Time in seconds the switch waits for a response from the authentication server
before resending the request.
Session Time
The amount of time the user is logged in.
MAC address
The supplicant MAC address.
Authentication Method
The authentication method used to establish the session.
Termination Cause
The reason for the session termination.
State
The current value of the Authenticator PAE state machine and of the Backend
state machine.
Authentication success
The number of times the state machine received a Success message from the
Authentication Server.
Authentication fails
The number of times the state machine received a Failure message from the
Authentication Server.
Field
Description
Содержание SBCEGBESW1
Страница 24: ...Using CLI 8 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 36: ...AAA Commands 20 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 56: ...Address Table Commands 40 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 136: ...IGMP Snooping Commands 120 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 159: ...Line Commands Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide 143...
Страница 160: ...Line Commands 144 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 168: ...Management ACL Commands 152 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 172: ...PHY Diagnostics Commands 156 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 180: ...Port Monitor Commands 164 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 213: ...QoS Commands Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide 197...
Страница 214: ...QoS Commands 198 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 238: ...RADIUS Commands 222 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 252: ...Web Server Commands 236 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 310: ...Spanning Tree Commands 294 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 322: ...SSH Commands 306 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 336: ...Syslog Commands 320 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 360: ...TACACS Commands 344 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 398: ...VLAN Commands 382 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...
Страница 424: ...408 Intel Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide...