Intel® Server System S9200WK Product Family Setup and Service Guide
70
4.16
Internal Chassis Rail Replacement
The systems within the Intel® Server System S9200WK product family include internal rails to support 1U
compute modules in the upper part of the inner walls of the chassis. Should the internal rails become
damaged or worn out, the following sections provide the instructions necessary to remove and replace them.
Required Tools and Supplies:
•
Anti-static wrist strap and conductive foam pad (recommended)
•
Flat head screwdriver
Note
: To maintain optimal performance of the system Intel recommends replacing ALL internal rails at once.
4.16.1
Internal Chassis Rail Removal
1.
Power the system down, remove it from the rack and place it on a flat surface.
Important Safety Note:
Due to the weight of a fully configured system, Intel® recommends using a
mechanical lift to aid with the removal of the system from the rack, and/or to use at least two people to
remove the system from the rack, or remove all installed compute modules from the system before
attempting to remove the system from the rack.
2.
Remove the compute modules from the bays selected for service (see Section 4.2.1)
Figure 81. Removing the internal chassis rail
3.
Using a flat head screwdriver, release the rail latch (see Letter A).
4.
Slide the rail towards the front of the chassis to remove it (see Letter B).