Intel® Server System S9200WK Product Family Setup and Service Guide
52
4.10.2.2
DIMM Installation
Figure 55. Installing the DIMM in a liquid cooled system
1.
Locate the DIMM slot for installation. Ensuring that the DIMM ejection tabs at both ends of the DIMM
slot are pushed outward to the open position (see Letter A). Use the provided tool if the DIMM
ejection tabs are in the closed position (see Section 4.10.2.1).
2.
Carefully unpack the replacement DIMM, taking care to only handle the device by its outer edges.
3.
Align the notch at the bottom edge of the DIMM with the key in the DIMM slot (see Letter B).
4.
Insert the DIMM into the slot (see Letter C) pushing down on the DIMM, until the ejection tabs snap
into place (see Letter D). Ensure that the ejection tabs are firmly in place (see Letter E).
Figure 56. Installing the DIMM retention clips
5.
If the replacement DIMM is 64GB in capacity, re-install the DIMM retention clip over the select DIMM
pair and heat spreader as shown in Figure 56. Ensure the clip is securely in place.