Intel® Server System S9200WK Product Family Setup and Service Guide
25
3.3
PCIe* Add-In Card
The following procedures are identical for both 1U and 2U riser card assemblies
3.3.1
Installing a PCIe* Add-In Card
Figure 17. Installing an add-in card
1.
Remove the compute module to be serviced from the server chassis and place it on to an anti-static
work surface (see Section 4.2.1)
2.
Remove the selected riser assembly from the compute module (see Section 0)
3.
If present, carefully remove the rear metal filler plate from the metal frame of the riser assembly (see
Letter A).
4.
Align the rear bracket of the add-in card to the rear opening of the riser assembly
5.
Carefully push the add-in card down into the PCIe slot (see Letter B).
6.
Ensure the add-in card is fully seated
7.
Re-install the riser card assembly into the compute module (see Section 4.3)
3.3.2
Removing a PCIe* Add-In Card
Figure 18. Removing an add-in card
1U riser card assembly shown**
1U Riser assembly shown **