BIOS Setup Interface
Intel®
Server Board S1200V3RP TPS
Revision 1.2
156
If enabled, the BMC will be detectable by OSes which support plug and play loading of
an IPMI driver. Do not enable this option if your OS does not support this driver.
Comments:
This option controls whether the OS Server Management
Software will be able to find the BMC and automatically load the correct IPMI support
software for it. If your OS does not support Plug & Play for the BMC, you will not have
the correct IPMI driver software loaded.
Back to [Server Management Screen]
— [Screen Map]
13. EuP LOT6 Off-Mode
Option Values:
Enabled
Disabled
Help Text:
Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off-Mode for near-zero energy use
when powered off.
Comments:
This option controls whether the system goes into “Deep Sleep” or
more conventional S5 “Soft-Off” when powered off. “Deep Sleep” state uses less energy
than S5 but S5 can start up faster and can allow a Wake on LAN action (which cannot
be done from a Deep Sleep state).
This option will not appear on platforms which do not support EuP LOT6 Off-Mode.
Back to [Server Management Screen]
— [Screen Map]
14. Console Redirection
Option Values:
<None>
Help Text:
View/Configure Console Redirection information and settings.
Comments:
Selection only.
Select this line and press the <Enter> key to go to
the Console Redirection group of configuration settings.
Back to [Server Management Screen]
— [Screen Map]
15. System Information
Option Values:
<None>
Help Text:
View System Information.