background image

What you will need to begin

   SAS 2.0 or SATA III hard disk drives (backward compatible to support 

SAS 1.0 or SATA II hard disk drives) for Intel

®

 Integrated RAID Module RMS25CB080,

RMS25CB040, and RMS25CB080N
     SATA III hard disk drives (backward compatible to support SATA II hard disk drives) 
for Intel

®

 Integrated RAID Module RMT3CB080

  Intel

®

 Integrated RAID Module RMS25CB080, RMS25CB040, RMT3CB080, or 

RMS25CB080N (SAS/SATA cables need to be prepared separately)

  SAS/SATA cable accessory kit, which can be ordered from Intel separately.

Please see the Tested Operating System List for available cable accessory kits at:

http://www.intel.com/p/en_US/support/server

  Intel

®

 Server Board with SAS Module connector

  Resource CD, which is shipped with systems or boards 

  Operating system installation media: Microsoft Windows Server 2003*, 

Microsoft Windows Server 2008*, Microsoft Windows Server 2012*, 
Microsoft Windows 7*, Microsoft Windows Vista*,Red Hat* Enterprise Linux, 
SUSE* Linux Enterprise Server, VMware* ESX Server 4, and VMware* ESXi 5.

Intel is a registered trademark of Intel Corporation or its 

subsidiaries in the United States and other countries.  

*Other names and brands may be claimed as the property 

of others. Copyright © 2014, Intel Corporation. All rights 

reserved.

Warning

 

Read all caution and safety 

 

statements in this document 

 

before performing any of the 

instructions. Also see the 

Intel

®

 

Server Board and Server Chassis

Safety Information

 document at:

http://www.intel.com/support/

motherboards/server/sb/cs-010770.

htm

 

for complete safety information.

Warning

 

Installation and service of 

 

this product should only be

 

performed by qualified service 

personnel to avoid risk of injury from 

electrical shock or energy hazard.

Caution

 

Observe normal ESD

 

[Electrostatic Discharge]

 

procedures during system 

integration to avoid possible 

damage to server board and/or 

other components.

Tools Required

        Anti-static

wrist strap

     Phillips*

screwdriver

Audible Alarm Information

For information about the audible alarm and how to silence or disable it, see the reverse side of this document.

Building Value with Intel®

Server Products, Programs, and Support

Get the high-value server solutions you 

need by taking advantage of the outstanding 

value Intel

®

 provides to system integrators:

For more information on Intel

®

's added-value

server offerings, visit the Intel

®

 ServerBuilder

website at: 

www.intel.com/go/serverbuilder

.

 Worldwide 24x7 technical support

  (AT&T Country Code + 866-655-6565)

1

 World-class service, including a 

  three-year limited warranty and Advanced 

  Warranty Replacement

1

 High-quality server building blocks

 Extensive breadth of server building blocks

 Solutions and tools to enable e-Business

 Product information, including 

  product briefs and technical product 

  specifications

 Sales tools, such as videos and 

  presentations

 Training information, such as the 

  Intel

®  

Online Learning Center

 Support Information and much more

Intel

®

 ServerBuilder is your one-stop 

shop for information about all of Intel

®

's 

Server Building Blocks such as:

1

Available only to Intel

®

 Channel Program

 Members, part of Intel

®

 e-Business Network.

Choosing the Right RAID Level

0

D4

D2

D4

D6

D8

Disk 2   

      

D4

D1

D3

D5

D7

Disk 1   

      

1

D4

D1

D2

D3

D4

Disk 2   

      

D4

D1

D2

D3

D4

Disk 1   

      

5

D4

D2

P

D5

D8

Disk 2   

      

D4

P

D4

D6

P

Disk 3   

      

D4

D1

D3

P

D7

Disk 1   

      

6

D4

D2

P1

P2

D7

Disk 2   

      

D4

P1

P2

D5

D8

Disk 3   

      

D4

P2

D4

D6

P1

Disk 4   

      

D4

D1

D3

P1

P2

Disk 1   

      

60

10

D4

D1

D3

D5

D7

Disk 2   

      

D4

D2

D4

D6

D8

Disk 3   

      

D4

D2

D4

D6

D8

Disk 4   

      

D4

D1

D3

D5

D7

Disk 1   

      

R1

R1

R0

50

D4

D1

P1

P2

D14

Disk 2   

      

D4

D2

D5

P1

P2

Disk 3   

      

D4

P2

D6

D10

P1

Disk 4   

      

D4

P1

P2

D9

D13

Disk 1   

      

D4

D3

P1

P2

D16

Disk 6   

      

D4

D4

D7

P1

P2

Disk 7   

      

D4

P2

D8

D12

P1

Disk 8   

      

D4

P1

P2

D11

D15

Disk 5   

      

R0

R6

R6

2

NONE

Striping (speed)

100%

Excellent Excellent

High throughput

workstation

2

1

Mirroring 

(redundancy)

50%

Very

good

Good

OS, apps

entry level

3

1

Striping and

distributed parity

(fault tolerance)

n-1

(67-94%)

Very

good

Good

Data, web/media

server

3

2

Striping with dual

distributed parity

n-2

(50-88%)

Good

Good

High fault

tolerance

4

1 per

mirror set

Striping across 

mirrors

50%

Very

good

Good

6

2 per R6

set

Striping across R6

arrays

n-4

(50-88%)

Very

good

Good

Critical data

6

1 per R5

set

Striping across R5

arrays

n-2

(67-94%)

Excellent

Very

Good

Database, file,

mail servers

Minimum

Physical

Drives

RAID

Fail PDs

Allowed

Method

Capacity

Read

Speed

Write

Speed

Good Usage

Database, file,

mail servers

D4

D2

P

D5

D14

D4

P

D6

D10

P

D4

D1

D5

P

D13

D4

D4

P

D11

D16

D4

P

D8

D12

P

D4

D3

D7

P

D15

Disk 1   

      

Disk 2   

      

Disk 3   

      

Disk 4   

      

Disk 5   

     

Disk 6   

    

R5

R0

R5

For more information on the jumpers referenced in this diagram, refer to the user guide located on the web at: 

http://www.intel.com/p/en_US/support/server/

2

Install the RAID Module

Power down the system and disconnect the power cord.

A
B
C

D

Remove the system cover.

Attach the RAID Module to the matching server board connector and 

press the module card firmly to engage the barrel standoffs.

The Intel

®

 Integrated RAID Module RMS25CB080 is shown for 

illustrative purpose.
Press down gently but firmly to ensure that the card is properly seated in 

the connectors, and then insert the four pin standoffs into the barrel 

standoffs respectively.

Intel® Integrated RAID Module
RMS25CB080, RMS25CB040, RMT3CB080,
and RMS25CB080N Reference Diagram

3

Connect the RAID Module

Connect the wide end of the provided cable to the top silver

connector (ports 0-3).

The Intel

®

 Integrated RAID Module RMS25CB080 is shown for

illustrative purpose.

A

Push the cable into the silver connector until it makes a slight click.

B

If using more than four drives, connect the wide end of the second

cable to the bottom silver connector (ports 4-7).

C

Connect the other ends of the cables to SATA drives or to the ports

on a SATA or SAS backplane.

Notes

:  Both non-expander backplanes (one cable per drive) and 

         expander backplanes (one or two total cables) are supported. 

         Drive power cables (not shown) are required.

D

Go to Step 4 on Side 2

Rear view of four SATA drives or backplane connected to ports 

on the Intel

®

 Integrated RAID Module RMS25CB080.

D

C

B

A

D

Ports 4-7

(This connector is not available on 

Intel

®

 Integrated RAID Module RMS25CB040 )

1

Installing the Barrel Standoff

Power down the system and disconnect the power cord.

A

Locate the matching SAS Module connector on your server board, 

see your server board documentation. 

B

Insert the barrel standoffs into the matching holes in the server board. 

The Intel

®

 Server Board S2600IP is shown for illustrative purpose.

C

Back View

SAS Module

Connector

Front View

J3A1

BBU/RMFBU

Connector

(This connector is

not available on 

Intel

®

 Integrated

RAID Module

RMS25CB080N)

 

J4A1

Ports 0-3

Speaker

J4B2

Advanced Software

Hardware Key Connector

J4B1

Ports 4-7

(This connector is

not available on 

Intel

®

 Integrated RAID Module

RMS25CB040)

 

Module Mounting

Holes

G42740-006

This guide contains step-by-step instructions for installing 
the Intel® Integrated RAID Module RMS25CB080, RMS25CB040,
RMT3CB080, and RMS25CB080N and information on using the

BIOS setup utility to configure a single logical drive array and

install the driver into the operating system. 

These guides and other supporting documents 
(including a list of supported server boards) are also located on the web at: 

http://www.intel.com.

For more advanced RAID configurations, or to install with other

operating systems, please refer to the 

Hardware User’s Guide

.

Read all cautions and warnings first before starting your RAID Controller 

integration.

If you are not familiar with ESD (Electrostatic Discharge) procedures used 
during system integration, see your 

Hardware Guide 

for complete ESD 

procedures. For more details on Intel® RAID controllers, see: 

www.intel.com/go/serverbuilder.

Intel® Integrated RAID Module
RMS25CB080, RMS25CB040, RMT3CB080,
and RMS25CB080N
Quick Start User's Guide

Intel® Integrated RAID Module RMS25CB080 as shown

Отзывы: