Calibrating Device with Custom Calibration Sample Application
26
Figure 4-2 Viewpoint #1
Press enter to capture the image. If successful, the frame counter on the lower right
corner will increase to 1/6 meaning 1 out of 6 images are captured. If it failed, a red
error message will appear and user is directed to retake a viewpoint.
4.3.2.2
Viewpoint #2 - Center Left
Move the device to the center left directly facing the target so the target covers much
of the left portion of the FOV.