Intel® Server S2600WF Product Family Configuration Guide
98
The following sections should be used to identify the appropriate data cables to order for specific drive configurations. Each section identifies the
data cable kits necessary to route between a given data source and the backplane of a specific Drive Bay Module location within the chassis.
Reference each drive bay module section as necessary to determine the cable requirements relevant to your specific drive bay configuration.
4.7.1
2U - 8x2.5” Drive Bay Module #1 – Cable Guide (with no SAS Expander)
4.7.1.1
Drive Bay Module # 1 - SAS/SATA Cable Guide
The following table identifies the appropriate SATA/SAS data cable kit(s) necessary to route data signals from Onboard SATA ports or available SAS
RAID mezzanine and PCIe add-in options to the 8x2.5” backplane installed to
Drive Bay Module #1
.
Table 59. Drive bay module #1 SAS/SATA cable guide
System
Configuration
SAS /SATA
Drive Support
SATA
Onboard Multi-port SATA Ports to
Backplane (BP) #1
SAS
Mezzanine 12 Gb SAS ROC Module to
Backplane (BP) #1
SAS
12 Gb SAS RAID PCIe* add-in card to
Backplane (BP) #1
Drive Bay #1
R2208WF…
8
R2224WF
Up to eight
2.5” SAS /
SATA Drives
SATA 0-3
BP 0-3
730mm HD --- HD
AXXCBL730HDHD
SATA 4-7
BP 4-7
730 mm HD --- HD
AXXCBL730HDHD
(2) 730mm Cables included with all WFT and
WF0 2.5” L6 Integrated systems
SAS Mezz
BP 0-3
730 mm HD --- HD
AXXCBL730HDHD
SAS Mezz
BP 4-7
730 mm HD --- HD
AXXCBL730HDHD
(2) 730mm Cables included with all WFT
and WF0 2.5” L6 Integrated systems
From Riser #1:
SAS PCIe
BP 0-3
730 mm HD --- HD
SAS PCIe
BP 4-7
730 mm HD --- HD
From Riser #2
SAS PCIe
BP 0-3
730 mm HD --- HD
SAS PCIe
BP 4-7
730 mm HD --- HD
A
XXCBL730HDHD
(2) 730mm Cables included with all 2.5” L6
Integrated systems
Drive Bay #1