4

General Installation Process

7

Install Memory Modules

DDR3 DIMM Memory Ide

ntification:

Other

Memory

DDR3

CAUTION: 

Observe normal ESD (ElectroStatic 

Discharge) procedures to avoid possible damage to 

system components.

DIMM notch and socket bump must align as shown below.

C

AIRFLOW

Chassis Front

2

3

1

4

A

B

TIM

D

CAUTION:

Do not 

over-tighten

fasteners.

E

Note: 

Heatsink styles may vary.

Remove the protective film on the TIM if present.

D

  CAUTION: The heatsink has thermal interface 

  material (TIM) on the underside of it. Use caution so 

     that you do not damage the thermal interface material.  

  Use gloves to avoid sharp edges.

E

C

A

B

Align heatsink fins to the front and back of 

the chassis for correct airflow. 

Airflow goes from front-to-back of chassis.

Each heatsink has four captive fasteners and 

should be tightened in a diagonal manner using 

the following procedure:

Using a #2 Phillips* screwdriver, 

start with screw 1 and engage screw 

threads by giving it two rotations 

and stop. (Do not fully tighten.)  
Proceed to screw 2 and engage screw 

threads by giving it two rotations and 

stop. Similarly, engage screws 3 and 4. 

Repeat steps C and D by giving each 

screw two rotations each time until 

each screw is lightly tightened up to 

a maximum of 8 inch-lbs torque.

6

Install Processor Heatsink

Install Memory Modules ...continued

Memory Configurations and Population Order:

Intel

®

 Server Board 

S1400SP

DI

M

M

_C

2

DI

M

M

_C

1

DI

M

M

_B

2

DI

M

M

_B

1

DI

M

M

_A

2

DI

M

M

_A

1

CPU Socket

Note:

 For additional memory configurations, see the 

Service Guide

 on the Intel

®

 Server Deployment & Management DVD that accompanied 

your Intel

®

 Server System, or go to:  

http://www.intel.com/p/en_US/support/ 

(post-production)

Memory sizing and configuration is supported only for qualified DIMMs approved by Intel

®

. For a list of supported memory, go to: 

http://serverconfigurator.intel.com/sct_app.aspx 

(post-production)

For the best performance, a minimum of three DIMMs per CPU is recommended, populated in the blue slot of each memory channel.

Содержание R1000SP

Страница 1: ...stall components If you are not familiar with ESD ElectroStatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...ard Riser Assembly 7 Install Add in Card 7 Install Add in Card Riser Assembly 8 Install Rack Handles 8 Install Intel I O Expansion Module optional 8 Install Intel RAID C600 Upgrade Key optional 8 Inst...

Страница 4: ...k of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2012 Intel Corporation All rights reserved...

Страница 5: ...Supply Hard Drive Bays Front Control Panel System Features and Components 3 5 Hard Drive Bay system as shown Useful Information The SCU1 4 7 port requires an Intel RAID C600 Upgrade Key installed to...

Страница 6: ...oard connections or install components 3 Remove the Air Duct Remove the air duct by lifting straight up IMPORTANT Before proceeding further check your Intel Server System for disconnected or loose cab...

Страница 7: ...with the two orientation posts on the socket A Install the processor as shown Orientation Posts Orientation Notches A A B C Close the load plate all the way as shown Install the Processor continued Ca...

Страница 8: ...s screwdriver start with screw 1 and engage screw threads by giving it two rotations and stop Do not fully tighten Proceed to screw 2 and engage screw threads by giving it two rotations and stop Simil...

Страница 9: ...Primary 8 x 2 5 hard drive bay as shown A B Remove the drive carrier by pressing the green latch to unlock Pull out the black lever and slide the carrier out Remove the four screws securing the plasti...

Страница 10: ...of the drive matches the backplane connector With the lever open insert the hard disk drive assembly into the chassis Push in the lever to lock it into place 4 x 3 5 hard drive bay as shown CAUTION If...

Страница 11: ...e optical device bay filler panel shown below This is required to maintain proper system cooling Rear View of Optical Drive A Install the plastic guide onto the back of the drive and attach with two s...

Страница 12: ...n e c t o r 17 Install Intel Remote Management Module 4 optional A d d i n C a r d Slots Hooks 13 Install Add in Card Riser Assembly Position the riser card edge connector over the server board riser...

Страница 13: ...stall Intel RAID Smart Battery optional A B A Locate the BBU bracket inside the chassis Align the tabs on the plastic battery holder with mounting holes on the BBU bracket B Slide the plastic battery...

Страница 14: ...rating system running insert the Intel Server Deployment Management DVD If using a Microsoft Windows operating system the Express Installer will autorun and allow you to select the appropriate drivers...

Страница 15: ...U FAN Main Power PS AUX Slot 6 PCI e_x16 RMM4 LITE TPM DIMM_C2 DIMM_C1 DIMM_B2 DIMM_B1 DIMM_A2 DIMM_A1 SYS FAN_3 SYS FAN_4 SYS FAN_1 SYS FAN_2 SYS FAN_5 CPU Power USB 4 5 LCP SCU 0 Jumper Blocks SCU 1...

Страница 16: ...N 5 FAN 1 FAN 2 Fixed System Fans Redundant System Fans 1 2 3 4 Air Flow Air Flow 1 2 3 4 5 A complete list of accessories and spares can be found at http www intel com p en_US support post production...

Страница 17: ...ard drive bay System Cabling Diagram 3 5 SATA HDD 7 Pin SATA 1x5 Pin SATA Pwr 3 5 SATA HDD 7 Pin SATA 1x5 Pin SATA Pwr 3 5 SATA HDD 7 Pin SATA 1x5 Pin SATA Pwr 3 5 SATA HDD 7 Pin SATA 1x5 Pin SATA Pwr...

Страница 18: ...nel USB FAN 1 FAN 2 SCU 0 PS AUX CPU Power SATA 1 SYS FAN_1 SYS FAN_2 SYS FAN_3 SYS FAN_4 SYS FAN_5 Intel Integrated RAID Module BBU Note To activate the port SCU1 4 7 on the server board a proper Int...

Страница 19: ...U Power SATA 1 Power Supply 450W SYS FAN_1 SYS FAN_2 SYS FAN_3 SYS FAN_4 SYS FAN_5 Intel Integrated RAID Module BBU Note To activate the port SCU1 4 7 on the server board a proper Intel RAID C600 Upgr...

Страница 20: ...G64256 003...

Отзывы: