To prepare for the installation, you will need the following: 

 

The utilities for your server board (available on the Intel

®

 Server Deployment Toolkit CD 

shipped with your server board) 

 

The latest FRU/SDR package, firmware update files, and Release Notes from 

http://support.intel.com/support/motherboards/server

 

To install the Professional Edition module, do the following: 

1.

 

Power down the system. 

2.

 

Remove AC power. 

3.

 

Open the chassis to gain access to the Intel Management Module Connector. 

4.

 

Insert the nylon standoff into the baseboard to support the Intel Management Module.  Choose 
the hole farthest away from the strap after the Intel Management Module is inserted into the 
connector. 

5.

 

Align the Management Module over the baseboard connector and the nylon standoff. 

6.

 

Press down on the Management Module to fully seat the connector and standoff. 

7.

 

Close the chassis, reconnect the AC power, and power-on the system. 

8.

 

Update the firmware and FRU/SDR for your server board.  Use the latest files and instructions 
for your server board that you downloaded from 

http://support.intel.com/support/motherboards/server

9.

 

Install ISM 8.20 from the ISM 8 Installation CD, or run the Intel

®

 Server Configuration Wizard 

(SCW) from the Intel Server Deployment Toolkit CD to configure the new features on the 
Professional Edition module. 

Removing the Intel Management Module—Professional Edition 

To remove the Professional Edition module, do the following: 

1.

 

Power down the system. 

2.

 

Remove AC power. 

3.

 

Open the chassis to gain access to the Intel Management module. 

4.

 

Pinch the end of the standoff and 

slightly

 raise the Management Module to disengage the 

standoff. To avoid damage to the connector, do not lift the edge the board that is farthest from 
the connector (near the standoff). 

5.

 

Using the strap attached to the module, gently pull up to slightly disengage the end of the 
connector closest to the strap.  Using your fingers, grasp the board near the other end of the 
connector and gently rock the board back and forth until the connector is completely 
disengaged. 

6.

 

Close the chassis and reconnect the AC power. 

Содержание Management Module

Страница 1: ...Intel Management Module Installation and User s Guide Document P N C81751 002...

Страница 2: ...GHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY...

Страница 3: ...e Intel Management Module Professional Edition 12 Installing the Intel Management Module Advanced Edition 13 Removing the Intel Management Module Advanced Edition 16 Intel Advanced Remote Server Contr...

Страница 4: ...4 Intel Management Module Installation and User s Guide...

Страница 5: ...Power Supply DIMM and hot swap controller FRU s The size of the System Event Log SEL is increased from 92 entries to 3276 entries The number of BMC users is increased from one anonymous user to four u...

Страница 6: ...ated NIC for the BMC on the Advanced Edition module The Intel Advanced Remote Server Control email alerting embedded CLI embedded web BMC resident SNMP agent SOL and other firmware resident features a...

Страница 7: ...l Management Module Advanced Edition installed on the managed server Embedded Web Server Intel Management Module Advanced Edition installed on the managed server Embedded CLI Telnet Server Intel Manag...

Страница 8: ...your server baseboard Location of Intel Management Module Header The following illustrations show the location of the Intel Management Module header on the Intel Server Board SE7520AF2 Intel Server Bo...

Страница 9: ...dule Installation and User s Guide 9 Figure 2 Location of Intel Management Module Connector on the Intel Server Board SE7520BD2 Figure 3 Location of Intel Management Module Connector on the Intel Serv...

Страница 10: ...10 Intel Management Module Installation and User s Guide Figure 4 Location of Intel Management Module Connector on the Intel Server Board SE8500HW4 Module Header...

Страница 11: ...of the standoff and retraction strap on the Professional Edition module the location is the same on the Advanced Edition module The upper illustration shows the bottom of the module The lower illustra...

Страница 12: ...date the firmware and FRU SDR for your server board Use the latest files and instructions for your server board that you downloaded from http support intel com support motherboards server 9 Install IS...

Страница 13: ...nagement Module Advanced Edition The following illustration shows the location of the standoff connector and retraction strap on the Advanced Edition module KEY A Location of the extraction strap B Lo...

Страница 14: ...ing illustration shows the network interface card filler panel and screws Figure 7 Intel Management Module Network Interface Card Rear Filler Panel and Screws 2 I2C Cables one long and one short cable...

Страница 15: ...rd SE7520JR2 install the NIC on the rear panel using 2 screws The following illustration shows the location of the network connector NIC3 on the rear panel of the Intel Server Chassis SR1400 NIC3 Repl...

Страница 16: ...e Advanced Edition module do the following 1 Power down the system 2 Remove AC power 3 Open the chassis to gain access to the Intel Management Module 4 Disconnect the cable to the NIC 5 Pinch the end...

Страница 17: ...wer application Run the Intel Server Configuration Wizard SCW on the Intel Server Deployment Toolkit CD to enable the KVM feature To use Intel Advanced Remote Server Control with the Advance Edition m...

Страница 18: ...Use the Intel Server Configuration Wizard to configure the email alerting feature You can configure the following parameters Number of supported alert configurations Email From To and Subject lines Al...

Страница 19: ...talling and using the OS specific SNMP Subagents refer to the Installing and Configuring the Intel Server Manager 8 SNMP Subagents document SNMP_Subagent_Install_and_Config_Guide pdf on the ISM 8 Inst...

Страница 20: ...lication 4 Set the SNMP community string to public to read the sensor data or private to use the SNMP SET commands The user has two SNMP SET commands available when using the BMC resident SNMP agent S...

Страница 21: ...erver also allows you to establish a Serial Over LAN SOL session To use the embedded CLI feature do the following 1 Connect to the Telnet server For example to Telnet to a server at IP address 222 222...

Страница 22: ...has six firmware resident web pages System Summary Page displays the overall system health and health indicators for individual sensors System Event Log displays selected number of records from the Sy...

Страница 23: ...nter problems connecting to the server try disabling automatic configuration of the browser LAN settings 2 The Embedded Web Server will prompt you for the BMC user name and password the first time you...

Страница 24: ...ate num CriticalUpdateRate num UsrUrl1 url on line help page URL UsrVal1 string navigation bar label the default is help UsrUrl2 url the default is support intel com UsrVal2 string navigation bar labe...

Страница 25: ...is enabled A FRAME FRAMESET Perl Script Example In the following example a Perl script sends an HTTP GET to the server Use IO Socket sock new IO Socket INET PeerAddr 222 222 39 10 PeerPort 80 Proto tc...

Страница 26: ...command syntax Table 4 Standard Return Values for CLI Commands ok unsupported command unrecognized command command time out insufficient privilege session in progress Table 5 Command Line Interface Sy...

Страница 27: ...atings nr non recoverable potential damage system hardware in jeopardy or damaged uf unspecified fault fault detected but severity unspecified status not available unknown typically because system pow...

Страница 28: ...on console Set session to system console for power on off Switch power off no OS shutdown cycle Switch power off then on no OS shutdown state Display target s current power state ON OFF power Operato...

Страница 29: ...d parameter mac ip subnet gateway Causes the BMC to generate an IPMI diagnostic interrupt NMI for IA 32 systems interrupt Operator console Switches to console mode and issues the interrupt version Cal...

Страница 30: ...or ON Application ON Button OFF NOTE Performing a graceful OS shutdown requires that an Intel supplied OS agent be present If this agent is not present or is unable to does not respond after 7 seconds...

Страница 31: ...rver Board SE7520BN2 User Guide provided with the server board and available on support intel com Intel Server Board SE8500HW4 User Guide provided with the server board and available on support intel...

Страница 32: ...board Video Mouse LED Light Emitting Diode mBMC mini Baseboard Management Controller National Semiconductor PC87431 MIB Management Information Base NIC Network Interface Card NMS Network Management St...

Отзывы: