![Intel IXF1104 Скачать руководство пользователя страница 214](http://html1.mh-extra.com/html/intel/ixf1104/ixf1104_datasheet_2073091214.webp)
Intel
®
IXF1104 4-Port Gigabit Ethernet Media Access Controller
Datasheet
214
Document Number: 278757
Revision Number: 009
Revision Date: 27-Oct-2005
16
Dat_prtyer_drp Port 0
SPHY/MPHY Mode:
Indicates whether to drop packets with data parity
error for port 0.
0 = Do not drop packets with data parity error
(default)
1 = Drop packets with data parity error
R/W
0
15:8
Reserved
Write as 0, ignore on Read.
R/W
00000000
7
Tx_parity_sense Port 3
SPHY Mode:
Indicates the parity sense to check the parity on
TDAT bus for port 3.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W
0
6
Tx_parity_sense Port 2
SPHY Mode:
Indicates the parity sense to check the parity on
TDAT bus for port 2.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W
0
5
Tx_parity_sense Port 1
SPHY Mode:
Indicates the parity sense to check the parity on
TDAT bus for port 1.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W
0
4
Tx_parity_sense Port 0
SPHY Mode:
Indicates the parity sense to check the parity on
TDAT bus for port 0.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
Indicates the parity sense to check the parity on
TDAT bus for all ports.
0 = Odd Parity
1 = Even Parity
R/W
0
3
Tx_port_enable Port 3
SPHY Mode:
0 = Disables the selected SPI3TX port 3.
1 = Enables the selected SPI3 TX port 3.
MPHY Mode:
0 = Disables the selected SPI3 TX port 3.
1 = Enables the selected SPI3 TX port 3.
R/W
1
Table 146. SPI3 Transmit and Global Configuration ($0x700) (Sheet 2 of 3)
Bit
Name
Description
Type
1
Default
1. RO = Read Only, No clear on Read; R = Read, Clear on Read; W = Write only; R/W = Read/Write, No
clear; R/W/C = Read/Write, Clear on Write