Click Add.
5
Choose the IP address of the trap receiver.
•
To use the PC you’re managing from, click This PC.
•
To send traps to another PC on the network, type the IP address
and community string of the PC you want to use.
6
Click OK, then click OK on the Device Setup dialog box.
Setting alarms
An alarm monitors a variable and generates an event (an SNMP trap,
log event, or both) when a limit is exceeded. The Quick Alarms dialog
box allows you to automatically set up rising alarms on these
commonly-used SNMP variables:
•
Network utilization exceeding 50%
•
Broadcast packets exceeding 3000 per second
•
CRC align errors exceeding 10 per second
•
Collisions exceeding 30000 per second
To set a Quick Alarm
1
Right-click the switch image.
2
On the menu that appears, click Monitoring, RMON, Alarms, and
Configure.
The Alarms Table dialog box appears.
3
Click Add.
The Quick Alarms dialog box appears.
Note
Press This PC in the Web
version of Intel Device View to
use the Web server as a trap
receiver.