background image

7

Safety Information

NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /

CAUTION

™

Danger of explosion if battery is incorrectly
replaced.

™

Replace only with the same or equivalent
type recommended by the manufacturer.

™

Dispose of used batteries according to the
manufacturer’s instructions.

Содержание GS-SR168

Страница 1: ...System Installation Guide GS SR168 1U Rack Mount Server Intel Pentium Xeon Processor Serverboard Rev 1001 25A080 01680 F00...

Страница 2: ...stallation 14 Step 3 4 Memory Installation 14 Step 3 5 PCI Expansion Card Installation 15 Step 3 6 Hard Disk Drive Installation 16 Step 3 7 FAN Duct Removal and Installation 17 Chapter 4 Appearance of...

Страница 3: ...ain 28 Advanced 31 PCI Configuration 32 Advanced Chipset Control 33 Advanced Processor Option 35 Peripheral Configuration 36 Hardware Monitor 40 Security 41 Server 43 Console Redirection 43 Boot 46 Ex...

Страница 4: ...geinstructions Do not use this product near water or a heat source Set up the product on a stable work surface or so as to ensure stability of the system Openingsinthecaseareprovidedforventilation Don...

Страница 5: ...s own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Neither the provider nor the manufacturer are responsible for any radio or televisi...

Страница 6: ...mentofCommunicationslabelidentifiescertifiedequipment Thiscertification meansthattheequipmentmeetscertaintelecommunicationsnetworkprotective operationalandsafety requirements TheDepartmentdoesnotguara...

Страница 7: ...ding The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100 for European users only...

Страница 8: ...ackages Whenopeningthepackage pleaseensure thesystemcomponentsarenotdamagedduringtheshipping Using the following checklist to verify the contents If any component is missing or damaged in the system p...

Страница 9: ...le bit Errors Correction Multiple Bit Errors Detection Expansion Slot 1 riser card supports 1 x 64 66MHz add on card 1 x PCI E x8 slot SATA RAID controller Intel 6300ESB Supports SATARAID 0 1 Cooling...

Страница 10: ...ed S1 S4 and S5 Server Management Functions Optional BMC Chip NS IPMI 1 5 controller FailureDetection IPMI 1 5 specification of Server management EventLogging 32KB Nonvolatile Memory to Log System Fai...

Страница 11: ...ystem Overview Chapter 2 System Overview A ChassisCover F HDD Blank B Motehrboard GA 9IVDPL G CD ROM Drive C Fan Duct H Back plane board D System Fans I Power E Riser Card Support A B C E D 3 6 F F G...

Страница 12: ...Step 1 Loosen the thumbscrew from the back of the server Step 2 Push down the indentation located at two sides of the chassis and slide toward to remove the top cover Step 3 Reverse Step 1 and 2 to r...

Страница 13: ...ep 2 Step1 Angling the rod to 65 degree maybe feel a kind of tight and then continue pull the rod to 90 degree when a noise cough made Step2 Locate Pin 1 in the socket and look for a golden cut edge o...

Страница 14: ...DIMM slot has a notch so the DIMM memory module can only fit in one direction 2 Insert the DIMM memory module vertically into the DIMM slot Then push it down 3 Close the plastic clip at both edges of...

Страница 15: ...the card size limitation Size limitation for PCI X height is 203 4 mm x 95 mm Step1 Lift the riser bracket slightly then pull it out from the server chassis Step2 Align the expansion card with the gui...

Страница 16: ...lank out of the drive bay Step 2 Remove the plastic hard disk tray Step 3 Slide hard disk into blank and secure it with screws Step 4 Toreplacetheharddriveblank slidetheblankintothebayuntilitlocksinto...

Страница 17: ...stallation Step 1 Pull up the screw holder and lossen the thumbscrews Lift up to remove the fan duct Step 2 For FAN Duct Installation place the fan duct on the top of heat sinks Fasten the screws to t...

Страница 18: ...8 GS SR168 Rack Mount Server 4 1 Front View of GS SR168 Chapter 4 Appearance of GS SR168 M O R D C e p y T m i l S r o t c e n n o C B S U s D E L 2 M O C r o F 5 4 J R s D D H A T A S p a w s y s a E...

Страница 19: ...nce 19 4 2 Rear View of GS SR168 r e w o P t r o P A G V t r o P M O C t o l S r e s i R r o t c e n n o C d r a o b y e K r o t c e n n o C e s u o M s r o t c e n n o C B S U s t r o P 2 1 N A L h c...

Страница 20: ...n o C n a F 1 F D b r o t c e n n o C n a F 2 F D c r o t c e n n o C n a F 3 F D d r o t c e n n o C n a F 4 F D e r o t c e n n o C n a F 5 F D f r o t c e n n o C n a F 6 F D g r o t c e n n o C n...

Страница 21: ...stem Not Ready Critical Fans Voltage TemperatureFailure IPMI Without IPMI With IPMI Name Power HDD LAN1 Activity LAN2 Activity Identification Color Condition Description Green On Power On Green Blink...

Страница 22: ...ver 4 5 LAN LED Description Color Condition Description Green ON LAN Link no Access Green BLINK LAN Access OFF Idle Yellow ON 1Gbpsconnection Green ON 100Mbpsconnection OFF 10Mbpsconnection Name LAN L...

Страница 23: ...23 ConnectorIconDescription 4 6 Connector Icon Description n o c I t s e g g u S n o i t p i r c s e D d r a o b y e K A G V e s u o M N A L t r o P l a i r e S B S U...

Страница 24: ...Layout Jumper Setting A B C E F G I H J K N L M F P O Q R D A CPU 0 O DDRII A3 B CPU1 P DDRII B3 C Intel MCH E7320 Q ATX1 D ATI Rage XL R ATX2 E Intel6300ESB F Intel 82541 G IT8712 F IX H IPMI Connec...

Страница 25: ...MOS Clear CMOS Function You may clear the CMOS data to its default values by this jumper Default value doesn t include the Shunter to prevent from improper use this jumper To clear CMOS temporarily sh...

Страница 26: ...al help only for Status Page Setup Menu and Option Page Setup Menu F2 Reserved F3 Reserved F4 Reserved F6 Reserved F7 Reserved F8 Reserved F9 LoadtheOptimizedDefaults F10 Save all the CMOS changes onl...

Страница 27: ...nalfeaturesenabled disabledsetupmenus z z z z z Boot Thissetuppageincludealltheitemsoffirstbootfunctionfeatures z z z z z Exit There are five optionsin this selection Exit Saving Changes Exit Discardi...

Страница 28: ...Menu Figure 1 will appear on the screen Use arrow keys to select among the items and press Enter to accept or enter the sub menu Figure 1 Main PhoenixBIOS Setup Utility Main Advanced Security Server...

Страница 29: ...hard disk vendor or the system manufacturer TYPE 1 39 Predefined types Users Set parameters by User Auto Set parameters automatically Default Vaules CD ROM Use for ATAPI CD ROM drives or double click...

Страница 30: ...formation This category includes the information of Processor Type Speed Extended memory BIOS Version BIOS Date System Product Name System serial number System version System UUID Main Board ID and Ma...

Страница 31: ...OS Setup Utility Main Advanced Security Server Boot Exit PCI Configuration Item Specific Help Advanced Chipset Control Advanced Processor Option Peripheral Configuration Hardware Monitor Reset Configu...

Страница 32: ...Enabled Enable onboard LAN 1 2 device Default value Disabled Disablethisfunction Option ROM Scan Enabled Enableing this item to initialize device expansion ROM Disabled Disablethisfunction Defualtvalu...

Страница 33: ...ser to function support for legacy USB Enabled Enables support for legacy USB Disabled Disables support for legacy USB Default Value PhoenixBIOS Setup Utility Advanced Chipset Control Item Specific He...

Страница 34: ...ty Mode Enabled Enables PCI E portA Device2 Default Value Disabled Disables this function 4GBPCIHoleGranularity Select the granularity of PCI hole for PCI resource If MTRRS are not enough we may use t...

Страница 35: ...isabled DisablesHyper ThreadingTechnologywhenusingotheroperating systems SetMaxExtCPUID 3 Set MAX CPUID extended function value to 3 Enabled Enable Set Max Ext CPUID 3 function Disabled Disable this f...

Страница 36: ...ative Mode Operation Auto SATA RAID Enable Disabled F1 Help KL Select Item Change Values F5 Setup Defaults Esc Exit IJ Select Menu Enter Select Sub Menu F10 Save Exit Serial Port A This allows users t...

Страница 37: ...IO address to 3E8 2E8 IRQ3 Set IO address to 2E8 Floppy disk controller Enabled Enable the floppy disk controller Default value Disabled Disable the device Floppy Check Enabled Enable the device to ve...

Страница 38: ...ation This option allows user to set the native mode for ATAfunction Note that certain OS is not supported under Native Mode Auto Autodetected Defaultvalue SerialATA Set Native mode to SerialATA Paral...

Страница 39: ...m without pressing power button Stay Off Keep the power off until the power button is pressed Pre State Set system to the last sate whenAC power is removed Do not power on system when AC power is back...

Страница 40: ...8V Detect system s voltage status automatically FAN RPM Display the current CPUs and Power FAN speed PhoenixBIOS Setup Utility Hardware Monitor Item Specific Help CPU 1 Temperature 38C 100F CPU 2 Temp...

Страница 41: ...d now will clear any previously entered password from the CMOS memory You will be asked to confirm the entered password Type the password again and press Enter You may also press Esc to abort the sele...

Страница 42: ...sword up to 6 characters in lengh and press Enter The password typed now will clear any previously entered password from the CMOS memory You will be asked to confirm the entered password Type the pass...

Страница 43: ...elect Item Change Values F5 Setup Defaults Esc Exit IJ Select Menu Enter Select Sub Menu F10 Save Exit PhoenixBIOS Setup Utility Console Redirection Item Specific Help Com Port Address Baud Rate 19 2K...

Страница 44: ...d by IEEE PC ANSI is the standard PC type terminal Note that for VT100 you must select English as your languuage And VT UTF8 uses unicode Options vt100 vt100 vt100 8bit PC ANSI 7bit PC ANSI VT UTF8 Fl...

Страница 45: ...l not stop for a keyboard or disk error it will stop for all other errors Default value MemoryRASFeatureControl Select specified features for DIMMs Sparing or Memory Mirroring Standard Select Standard...

Страница 46: ...r on Boot Device Priority Removable Device Hard Drive CD ROM Drive These three fields determines which type of device the system attempt to boot from after PhoenixBIOS Post completed Specifies the boo...

Страница 47: ...play the following sub menu Exit Saving Changes Exit Discarding Changes Load Settup Default Discard Change Save Changes PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Exit Saving Ch...

Страница 48: ...ws user to load default values for all setup items When you press Enter on this item you will get a confirmation dialog box with a message as below ExitDiscarding Changes This option allows user to ex...

Страница 49: ...firmation dialog box with a message as below Save Changes This option allows user to save setup dat ato CMOS When you press Enter on this item you will get a confirmation dialog box with a message as...

Страница 50: ...uity RIMM CNR Communication and Networking Riser DMA Direct Memory Access DMI DesktopManagementInterface DIMM Dual Inline Memory Module DRM DualRetentionMechanism DRAM Dynamic Random Access Memory DDR...

Страница 51: ...Translator Hub MPT MemoryProtocolTranslator NIC Network Interface Card OS Operating System OEM OriginalEquipmentManufacturer PAC PCI A G P Controller POST Power On Self Test PCI PeripheralComponentIn...

Страница 52: ......

Отзывы: