Intel Express 210T Скачать руководство пользователя страница 11

9

Stacking Hubs

Why Stack?

The Express 220T and 210T hubs use the same connectors so they can be
stacked together or stacked in combination with the Express 10/100
Stackable hub. By stacking Intel hubs you can:

• increase the number of available ports, yet still treat the stack as a

single repeater.

• use a single Management Module to manage all hubs in the stack.

• use the 220T’s internal bridge so 10Mbps and 100Mbps segments can

communicate.

Guidelines

• You must use an Intel Cascade Cable to stack the hubs. Do not daisy-

chain hubs operating at 100Mbps with UTP cable.

• A stack can consist of any combination of 220T, 210T, or

Express 10/100 hubs (12- or 24-port versions).

• You can stack up to eight hubs.

• When cabled correctly, the top hub in a stack is numbered hub 1.

• If there is more than one 220T hub in a stack, only one bridge is active

at a time. The lowest numbered 220T hub is the active bridge.

• All devices at the same speed are in the same segment. For example, all

devices at 10Mbps are in one segment and all devices at 100Mbps are
in another.

Input
  100-120VAC/2.5A
  200-240VAC/1.5A
  47Hz-63Hz

Redundant Power Supply (RPS)

Input
  100-120VAC/2.5A
  200-240VAC/1.5A
  47Hz-63Hz

Redundant Power Supply (RPS)

Input
  100-120VAC/2.5A
  200-240VAC/1.5A
  47Hz-63Hz

Redundant Power Supply (RPS)

Hub 1

Hub 2

Hub 3

Intel Cascade
Cable (EE200CC)

Express 220T Hub

Intel Cascade

Cable

Can

stack

with

Express 210T Stackable Hub and
Express 10/100 Stackable Hub
(12- or 24-port versions).

+

Colls 10Mbps

Colls 100Mbps

RPS

Power

Intel Express 220T 
Stackable Hub

Bridged

Managed

Enable/Disable 
Bridging

Status

Class  

I

Left (Orange/Green)
   Orange = 10Mbps
   Green = 100Mbps 
   Solid = Link
   Blink = Activity

Right (Yellow)
   Solid = Disabled
   Blink = Wrong speed

1

2

3

4

5

6

7

8

9

10

11

12

10Base-T

100Base-TX

Power

Intel Express 210T 
Stackable Hub

Collision

Managed

Status

Class  

I

Left (Green)
   Solid = Link
   Blink = Activity

Right (Yellow)
   Solid = Disabled
   Blink = Wrong speed

Change Hub Speed

1

2

3

4

5

6

7

8

9

10

11

12

10Base-T

100Base-TX

Power

Intel Express 
10/100 Stackable Hub

Collision

Managed

Status

Class  

I

Left (Green)
   Solid = Link
   Blink = Activity

Right (Amber)
   Solid = Disabled
   Blink = Wrong speed

Change Hub Speed

24

23

22

19

21

20

16

17

18

10

11

12

15

14

13

8

7

6

5

4

9

1

2

3

Connect the Cacade
Cables to the hubs as
shown in the diagram.

Содержание Express 210T

Страница 1: ...Intel Express 220T and 210T Stackable Hubs User Guide...

Страница 2: ...mpanies and are used only for explanation and to the owners benefit without intent to infringe First Edition May 1998 694466 001 Year 2000 Capable An Intel product when used in accordance with its ass...

Страница 3: ...Connecting to Devices 8 Connection Guidelines 8 Stacking Hubs 9 Why Stack 9 Bridging Segments 10 Bridging 220T Hubs 10 Bridging 210T Hubs 11 Cabling Devices 12 Media Requirements 12 Straight through v...

Страница 4: ...ps Green 100Mbps Solid Link Blink Activity Right Yellow Solid Disabled Blink Wrong speed Intel Express 220T Stackable Hub 24 23 22 19 21 20 16 17 18 10 11 12 15 14 13 8 7 6 5 4 9 1 2 3 10Base T 100Bas...

Страница 5: ...ress 210T Stackable Hub Collision Managed Status Class I Left Green Solid Link Blink Activity Right Yellow Solid Disabled Blink Wrong speed Change Hub Speed 1 2 3 4 5 6 7 8 9 10 11 12 10Base T 100Base...

Страница 6: ...ing yellow and Out of specification cabling or port hardware Status LED blinking problem Try a different cable Partitioned ports A port is automatically disabled partitioned by the hub when an invalid...

Страница 7: ...detected on 100Mbps segment RPS On green Optional RPS is present and on standby Off No RPS unit present On red RPS is active hub power supply failed Bridged On 10Mbps and 100Mbps segments can communi...

Страница 8: ...ort hardware Status LED blinking problem Try a different cable Partitioned ports A port is automatically disabled partitioned off by the hub when an invalid condition occurs such as too many consecuti...

Страница 9: ...Collision Blinking Collisions detected on hub or stack LED brightens as more collisions are detected Continuous blinking indicates an overloaded network Off No collisions detected Managed On Hub is m...

Страница 10: ...ory 5 unshielded twisted pair CAT 5 UTP cable when connecting 100Mbps devices to the hub Use Category 3 4 or 5 unshielded twisted pair CAT 3 4 5 UTP cable when connecting 10Mbps devices to the hub Lim...

Страница 11: ...n another Input 100 120VAC 2 5A 200 240VAC 1 5A 47Hz 63Hz Redundant Power Supply RPS Input 100 120VAC 2 5A 200 240VAC 1 5A 47Hz 63Hz Redundant Power Supply RPS Input 100 120VAC 2 5A 200 240VAC 1 5A 47...

Страница 12: ...f that hub fails or is removed the next 220T automatically provides bridging for the stack When active the Bridged LED is illuminated on all hubs in the stack Pressing the Enable Disable Bridging butt...

Страница 13: ...al ports that can operate at 10Mbps or 100Mbps to bridge hubs 100Mbps 10Mbps 10Mbps 100Mbps Example 3 Bridging with an Ethernet Module Another way to bridge segments is to use an Ethernet Module Plug...

Страница 14: ...specification allows you to use CAT 3 CAT 4 or CAT 5 UTP cabling You re limited to 100 meters between any two devices 100Base FX The optional Fiber Module lets you connect to a switch bridge or router...

Страница 15: ...Not used 5 Not used 7 Not used 7 Not used 8 Not used 8 Not used 1 RX 1 TX 2 RX 2 TX 3 TX 3 RX 6 TX 6 RX Crossover UTP cable Hub MDI X Switch MDI X 100 4 Not used 4 Not used 5 Not used 5 Not used 7 No...

Страница 16: ...owever the hubs operating at 10Mbps and the hubs operating at 100Mbps are on separate network segments To enable the segments to communicate add a 220T hub to the stack or use another device to bridge...

Страница 17: ...a single stack I have a 210T hub at 10Mbps and another 210T at 100Mbps connected with an Intel Cascade Cable Can they talk to each other No All 210T hubs operating at 100Mbps are in one segment or col...

Страница 18: ...fice environment Choose a site that is Clean and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight Away from sources of vib...

Страница 19: ...gnetici prodotti da dispositivi elettrici In aree soggette a temporali consigliabile collegare il sistema ad un limitatore di corrente In caso di temporali scollegare le linee di comunicazione dal mod...

Страница 20: ...ined in this product are covered by Intel s limited warranty for this product the product may contain fully tested recycled parts warranted as if new For warranty information call one of the numbers b...

Страница 21: ...limited warranty for this product the product may contain fully tested recycled parts warranted as if new For warranty information call one of the numbers below Returning a Defective Product RMA Befo...

Страница 22: ...linking erratically The port is partitioned auto disabled This condition is usually caused by a malfunctioning network adapter or an overloaded network segment For more information see page 4 Intermit...

Страница 23: ...r support services You can purchase a range of support services including 24 hour support per incident support on site service and software and hardware maintenance agreements For details about the In...

Страница 24: ......

Отзывы: