Electrical Specifications
18
Datasheet
2.4
Market Segment Identification (MSID)
The MSID[1:0] signals may be used as outputs to determine the Market Segment of
provides details regarding the state of MSID[1:0]. A circuit can
be used to prevent 130 W TDP processors from booting on boards optimized for 65 W
TDP.
2.5
Reserved, Unused, and TESTHI Signals
All RESERVED lands must remain unconnected. Connection of these lands to V
CC
, V
SS
,
V
TT
, or to any other signal (including each other) can result in component malfunction
or incompatibility with future processors. See
processor and the location of all RESERVED lands.
In a system level design, on-die termination has been included by the processor to
allow signals to be terminated within the processor silicon. Most unused GTL+ inputs
should be left as no connects as GTL+ termination is provided on the processor silicon.
However, see
for details on GTL+ signals that do not include on-die termination.
Unused active high inputs, should be connected through a resistor to ground (V
SS
).
Unused outputs can be left unconnected, however this may interfere with some TAP
functions, complicate debug probing, and prevent boundary scan testing. A resistor
must be used when tying bidirectional signals to power or ground. When tying any
signal to power or ground, a resistor will also allow for system testability. Resistor
values should be within ± 20% of the impedance of the motherboard trace for front
side bus signals. For unused GTL+ input or I/O signals, use pull-up resistors of the
same value as the on-die termination resistors (R
TT
). For details, see
TAP and CMOS signals do not include on-die termination. Inputs and used outputs must
be terminated on the motherboard. Unused outputs may be terminated on the
motherboard or left unconnected. Note that leaving unused outputs unterminated may
interfere with some TAP functions, complicate debug probing, and prevent boundary
scan testing.
All TESTHI[13:0] lands should be individually connected to V
TT
via a pull-up resistor
that matches the nominal trace impedance.
Table 3.
Market Segment Selection Truth Table for MSID[1:0]
1
,
2
,
3
,
4
NOTES:
1.
The MSID[1:0] signals are provided to indicate the Market Segment for the processor
and may be used for future processor compatibility or for keying. Circuitry on the
motherboard may use these signals to identify the processor installed.
2.
These signals are not connected to the processor die.
3.
A logic 0 is achieved by pulling the signal to ground on the package.
4.
A logic 1 is achieved by leaving the signal as a no connect on the package.
MSID1
MSID0
Description
0
0
Intel
®
Core™2 Duo desktop processor E6000 and E4000 sequence and the
Intel
®
Core™2 Extreme processor X6800
0
1
Reserved
1
0
Reserved
1
1
Reserved
Содержание CORE 2 DUO E4000 - 3-2008
Страница 8: ...8 Datasheet ...
Страница 10: ...10 Datasheet ...
Страница 36: ...Electrical Specifications 36 Datasheet ...
Страница 38: ...Package Mechanical Specifications 38 Datasheet Figure 9 Processor Package Drawing Sheet 1 of 3 ...
Страница 39: ...Datasheet 39 Package Mechanical Specifications Figure 10 Processor Package Drawing Sheet 2 of 3 ...
Страница 40: ...Package Mechanical Specifications 40 Datasheet Figure 11 Processor Package Drawing Sheet 3 of 3 ...
Страница 46: ...Package Mechanical Specifications 46 Datasheet ...
Страница 100: ...Features 100 Datasheet ...
Страница 110: ...Boxed Processor Specifications 110 Datasheet ...
Страница 122: ...Debug Tools Specifications 122 Datasheet ...