Hardware Installations and Upgrades
20
Intel
®
Compute Module MFS2600KI User Guide
6.
Holding the mezzanine card by its edges, gently lift it from the connectors and store it in an
anti-static package.
7.
Using a 1/4-inch nut driver, remove the standoffs.
8.
Using a Phillips* screwdriver, secure the four screws (that were previously removed) into the
holes vacated by the standoffs.
9.
Reinstall the top cover. For instructions, see
Installing a Compute Module into the Chassis
Page 8.
10.
Reinstall the server compute module in the chassis. For instructions, see
on Page 8.
Replacing the CMOS Battery
The lithium battery on the server board powers the RTC for up to 10 years in the absence of power.
When the battery starts to weaken, it loses voltage, and the server settings stored in the CMOS
RAM (for example, the date and time) may be wrong. Contact your customer service representative
or dealer for a list of approved replacement batteries.
Warning:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries according to
manufacturer’s instructions.
Advarsel:
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri
af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
Advarsel:
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning:
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som
rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
Varoitus:
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
To replace the battery, follow these steps:
1.
Observe the safety and ESD information at the beginning of this manual and in the appendices.
2.
If the compute module is installed in a chassis, remove it. For instructions, see
Compute Module from the Chassis
on Page 7.
3.
Remove the top cover. For instructions, see
on Page 8.
4.
5.
Insert the tip of a small flat-head screwdriver, or equivalent, under the tab in the plastic retainer.
Gently push down on the screwdriver to lift the battery.
6.
Remove the battery from its socket.
7.
Dispose of the battery according to local ordinance.
8.
Remove the new lithium battery from its package, and, being careful to observe the correct
polarity, insert it in the battery socket.