Independent Loading Mechanism (ILM)
36
Thermal/Mechanical Specifications and Design Guide
Note:
is for or illustration only and may not show most current parts.
1. Carefully lower the ILM load plate on top of the processor,
2. Verify that Load-lever-cam is over the load-plate-tab; actuate Load lever with a
smooth uniform motion and latch to the ILM (with thumb).
3. Close the Hinge lever with a smooth uniform motion and latch to the ILM.
4.5
ILM Cover
Intel has developed a cover that will snap on to the ILM for the LGA2011 socket family.
The ILM cover is intended to reduce the potential for socket contact damage from the
operator / customer fingers being close to the socket contacts to remove or install the
pick and place cover. By design the ILM cover and pick and place covers can not be
installed simultaneously.
The ILM cover concept is shown in
.
This cover is intended to be used in place of the pick and place cover once the ILM is
assembled to the board. The ILM will be offered with the ILM cover pre assembled as
well as a discrete part.
Figure 4-12. Pin 1 Markings on the ILM Frame
Figure 4-13. Closing ILM and Loadplate
Содержание BX80619I73820
Страница 10: ...10 Thermal Mechanical Specifications and Design Guide...
Страница 14: ...Introduction 14 Thermal Mechanical Specifications and Design Guide...
Страница 104: ...Thermal Solutions 104 Thermal Mechanical Specifications and Design Guide...
Страница 112: ...Mechanical Drawings 112 Thermal Mechanical Specifications and Design Guide...
Страница 118: ...Socket Mechanical Drawings 118 Thermal Mechanical Specifications and Design Guide...
Страница 124: ...Package Mechanical Drawings 124 Thermal Mechanical Specifications and Design Guide...