Intel BB5000XALR Скачать руководство пользователя страница 7

Monthly Specification Update 

Enterprise Platforms and Services Marketing 

 

 

Preface 

This document communicates product Errata and Documentation Changes and Corrections for 
the following Intel Server Products:  

  Intel

®

 Server Board S5000PAL 

  Intel

®

 Server Board S5000XAL 

  Intel

®

 Server Chassis SR1500 

  Intel

®

 Server Chassis SR1550 

  Intel

®

 Server Chassis SR2500 

  Intel

®

 Server System SR1500AL 

  Intel

®

 Server System SR1550AL 

  Intel

®

 Server System SR2500AL 

Refer to the 

Dual-Core Intel

®

 Xeon

®

 Processor 5000 Sequence

 

Specification Update

 (Order 

Number: 313065) for specification updates concerning the Dual-Core Intel

®

 Xeon

®

 Processor 

5000 Series processors. Items contained in the 

Dual-Core Intel

®

 Xeon

®

 Processor 5000 

Sequence

 

Specification Update

 that do not apply to the products in this document or were 

worked around are noted in this document. Otherwise, it should be assumed that any processor 
errata for a given stepping are applicable to the Printed Board Assembly (PBA) revisions(s) 
associated with that stepping. 

This document communicates the following types of changes:  

 

Specification Changes

 are modifications to the current published specifications for a 

given product. These include typos, errors, or omissions. The next release of the 
document will incorporate the specified changes. 

 

 

Specification Clarifications

 describe a supported feature or function in greater detail or 

further highlight their impact to a complex design requirement. The next release of the 
document will incorporate these clarifications. 

 

 

Errata 

are design defects or deviations from current published specifications for a given 

product. Published errata may or may not be corrected. Hardware and software 
designed to be used with any given processor stepping must assume that all errata 
documented for that processor stepping is present on all devices. 

  
 

Содержание BB5000XALR

Страница 1: ...Intel Server Board S5000PAL Intel Server Board S5000XAL Intel Server System SR1500AL Intel Server System SR1550AL Intel Server System SR2500AL Intel Order Number D65289 036 October 2011 Enterprise Pla...

Страница 2: ...d Disclaimers The Intel Products Specified may contain design defects or errors known as errata that may cause the products to deviate from the published specifications Current characterized errata ar...

Страница 3: ...Monthly Specification Update Enterprise Platforms and Services Marketing iii Copyright Intel Corporation 2006 2011...

Страница 4: ...te a SEL event 8 13 Power supply redundancy state is misleading when only one power supply is installed 9 14 Hot swap Controller HSC and Local Control Panel LCP updates may take a long time 9 15 Conso...

Страница 5: ...Expansion Module may not properly reset 18 39 SAS drive in a ROMB RAID 5 may drop offline during a reboot in the Intel Server System SR2500PALLX 19 40 Intel Server System SR2500ALLX sixth hard drive f...

Страница 6: ...lt to Install in Intel Server System SR2500AL and Intel Server Chassis SR2500 29 64 System May not Boot After Multiple DC power Cycles with BIOS Revision R009830 65 System will not skip CD DVD drive w...

Страница 7: ...ted in this document Otherwise it should be assumed that any processor errata for a given stepping are applicable to the Printed Board Assembly PBA revisions s associated with that stepping This docum...

Страница 8: ...after a DC cycle 10 Fixed Fans may run faster than expected after exiting BIOS setup 11 Fixed System fault LED may report incorrect status for some events 12 Fixed Fan removal does not generate a SEL...

Страница 9: ...BMC firmware with previous versions of BIOS cause system POST failure 44 Fixed Intel Server System SR2500ALLX may operate louder than expected 45 No Fix Red Hat Enterprise Linux may report the wrong...

Страница 10: ...tion Change 1 Fixed Intel Server Board S5000PAL S5000XAL Technical Product Specification Rev 1 1 The SMBUS block diagram Figure 16 as provided in Rev 1 1 of the Intel Server Board S5000PAL S5000XAL TP...

Страница 11: ...ing an active serial over LAN connection or an active IPMI over LAN connection to the BMC the connection may be intermittently lost during a DC cycle or reset Implication The user s connection may be...

Страница 12: ...espond as though this fan has failed and fan redundancy is lost This causes the system fault LED and fan status LED to indicate a failure for this sensor In addition the fans will run in a high speed...

Страница 13: ...button responds Problem The BMC requires approximately 35 seconds to fully initialize the system after an AC cycle before the system can be powered on Implication After an AC cycle a user must wait a...

Страница 14: ...for some events Problem The system fault LED may report incorrect status for some events The proper LED state is described in the server board TPS but some events may not reflect the states described...

Страница 15: ...and Local Control Panel LCP updates may take a long time Problem The Hot Swap Controller HSC and Intel Local Control Panel LCP updates may take a long time The time to complete each update could exce...

Страница 16: ...II option is not enabled in initial BIOS release Problem The Intel Embedded Server RAID Technology II feature that was available in pre production BIOS releases is not available in the initial product...

Страница 17: ...500AL show a Changes in Hardware or Drivers Detected error message during WHQL ACPI stress testing Problem While running Microsoft Windows Hardware Compatibility Test HCT 12 1 ACPI stress device I O o...

Страница 18: ...They cannot use this utility to add a microcode patch to the existing BIOS 23 Intel RAID Controller SRCSAS144E causes systems to reset multiple times before completing POST Problem With the Intel RAI...

Страница 19: ...cap extension It is important you include the cap extension in the file name otherwise the Change Logo Utility saves the file with the incorrect extension If you forget to include the cap in the file...

Страница 20: ...eo controller via the BIOS setup No workaround exists for configurations that do not include video controller support 28 The SMBIOS entry point may not be visible under certain hardware configurations...

Страница 21: ...um is fixed since BIOS release R0061 and later releases Workaround None 30 SuSE Linux Enterprise Server may not install successfully with Intel Embedded Server RAID Technology II enabled Problem If Su...

Страница 22: ...nd the BIOS setup and is not an incorrect display by the operating system Workaround None 32 Change Logo Utility causes BIOS corruption Problem Any board flashed with a version of BIOS release R0064 e...

Страница 23: ...rning message may be displayed in the Intel RAID Web Console 2 utility however there seem to be no functional issues with the system Implication This warning message is only seen in Microsoft Windows...

Страница 24: ...d drives for use with Intel Server Systems Problem Some desktop class hard disk drives show performance loss and in some cases take the drive offline when running in an enterprise environment Implicat...

Страница 25: ...System SR2500PALLX Implication This only happens with specific drives Updating the drive s firmware to the latest version should resolve this issue Status This erratum is fixed by updating SAS drive f...

Страница 26: ...ives may not be detected or may go offline in the Intel Server System SR2500ALBRP when operating at SATA 3GB s data rate Problem In the Intel Server System SR2500ALBRP with a passive midplane hard dri...

Страница 27: ...ouder than expected Problem The Intel Server System SR2500ALLX may operate louder than expected Implication The abnormal noise is caused by the two unbalanced 60 mm system fans 5 and 6 Using a FRUSDR...

Страница 28: ...ed in System Event Log SEL after system power on Problem An IERR or thermal trip event may be reported in the System Event Log SEL after the system is powered on The system status LED on the front pan...

Страница 29: ...soft Windows operating systems that you can ignore Workaround Use a PS 2 keyboard and mouse 49 Microsoft Windows and Intel RAID Web Console II report an error when the ASR2500SATAPE kit is used Proble...

Страница 30: ...or 81 prior to installing the appropriate service pack the system will display the blue screen Starting in BIOS 79 support for enhanced sleep states was added This addition to the BIOS requires that t...

Страница 31: ...coustics Mode in the BIOS are actually being set up in a fail safe state Status This erratum is fixed in BMC 62 and later releases Workaround None 53 Downgrading the firmware of the Integrated RAID RO...

Страница 32: ...wn with a specific version of Intel I OAT driver Problem Microsoft Windows 2003 R2 SP2 may display blue screen during an operating system boot or shutdown The issue occurs only with ver 1 2 78 6 of th...

Страница 33: ...the 5400 series in the Intel S5000PAL Server Board and install Microsoft Windows Server 2008 on the system you may encounter the following error in the Windows event log The Event Error is related to...

Страница 34: ...on Intel Server Board S5000PSL Intel Server Board S5000PAL Intel Server Board S5000VSA Intel Server Board S5000VCL and Intel Workstation Board S5000XVN There are two types of test options when a cust...

Страница 35: ...during Login or Shutdown Problem Installing the Intel PRO 1000 PT Quad Port Low Profile Server Adapter Model EXPI9404PTL may hang the system at the login screen or when shutting down This has been rep...

Страница 36: ...tion have been configured as enabled in BIOS setup Status This issue may be fixed in a future BIOS revision Workaround A soft system reboot CTL ALT DEL will result in a subsequent successful completio...

Страница 37: ...550AL families and server base board S5000PAL BB5000XAL families have this problem Status Not fixed Workaround None 68 Please do not downgrade BIOS from factory shipped BIOS 101 to any previous versio...

Страница 38: ...E10103 018 SR1550ALRNA 900397 E10102 017 E10102 018 SR2500ALLXR 900362 E10105 016 E10105 017 Status Not fixed Workaround None 69 The Serial Port Console Redirection displays the Adaptec 5805 RAID Con...

Страница 39: ...m The current diagram does not reflect the following board design changes made to the final production level server board Add PECI controller Remove separate HSC connector Correct Midplane FP SMBus co...

Страница 40: ...design Problem Current diagram does not reflect changes incorporated into the final production level server board MCH FBDIMM 1 5 Vreg moved from 12 V rail to 5 V rail Video Memory Vreg corrected to o...

Страница 41: ...SR2500AL TPS should swap the descriptions of items A and K Problem The current diagram swaps the descriptions of items A and K Item A should be the battery connector it is incorrectly described as the...

Страница 42: ...cal Product Specification 4 Front panel pin out in the Intel Server Board S5000PAL Quick Reference Label is incorrect Problem The current diagram incorrectly lists a cooling status pin does not have t...