background image

Intel

®

 RAID Module  

RMS2LL040(AXXRMS2LL040) and 

RMS2LL080(AXXRMS2LL080)  

Hardware User’s Guide

Intel Order Number: E97251-002

Содержание AXXRMS2LL040

Страница 1: ...Intel RAID Module RMS2LL040 AXXRMS2LL040 and RMS2LL080 AXXRMS2LL080 Hardware User s Guide Intel Order Number E97251 002...

Страница 2: ...INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel product...

Страница 3: ...ok are Engineers who are designing an Intel RAID Module RMS2LL040 or RMS2LL080 for their RAID system Anyone installing an Intel RAID Module RMS2LL040 or RMS2LL080 in their RAID system Organization Thi...

Страница 4: ...iv Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...

Страница 5: ...ng the RAID Module 5 Chapter 3 Intel RAID Module RMS2LL0x0 Characteristics 9 Major Components 12 LSI LSISAS2008 Processor Chip 12 Flash ROM 13 Boot Strap ROM SEEPROM 13 Diagnostic Components 13 SAS SA...

Страница 6: ...Bus and ID Mapping 22 Appendix A Drive Roaming Install 23 Drive Roaming 23 Appendix B Installation Assembly Safety Instructions 25 Deutsch 28 Fran ais 29 Espa ol 31 Italiano 32 Appendix C Regulatory...

Страница 7: ...AID Module RMS2LL0x0 6 Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Figure 4 Card Layout 9 Figure 5 RMS2LL040 Hardware Block Diagram 11 Figure 6 RMS2LL080 Hardware Block Di...

Страница 8: ...viii Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...

Страница 9: ...f Tables Table 1 Jumper Description 10 Table 2 SAS SATA Connector Pin out 15 Table 3 Host Board Interface Connector Pin Out 17 Table 4 Technical Specifications 18 Table 5 Array Performance Features 19...

Страница 10: ...x Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...

Страница 11: ...er pin counts and lower power requirements than parallel SCSI Benefits of SAS and SATA SAS is a serial point to point enterprise level device interface that leverages the proven SCSI protocol set SAS...

Страница 12: ...20UR Intel Server Board S5520HC S5520HCT Intel Server Board S5500HCV Intel Workstation Board S5520SC Intel Server Board S3420GP Intel Server System SR1600UR Intel Server System SR2600UR Intel Server S...

Страница 13: ...system list for your server board at http www intel com support go motherboards server index htm To make sure the RAID module supports your operating system see also the Tested Hardware and Operating...

Страница 14: ...ts for drives in IR mode Firmware provides best effort to recognize an error and recover from it if possible Failures are logged from controller and drive firmware Failures are logged in Intel RAID We...

Страница 15: ...teps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server system documentation 3 Insert the...

Страница 16: ...connecting the recommended Right angle end or Vertical end of the SAS SATA cable to the SAS connectors of the controller see your server workstation board or chassis documentation Make sure the cables...

Страница 17: ...SAS cables carefully Use only straight SAS cables not cross over SAS cables Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Install the server system cover and connect the pow...

Страница 18: ...ule RMS2LL0x0 installation you must configure the storage adapter and install the operating system driver The Intel RAID Software User s Guide Document Number D29305 0xx provides configuration options...

Страница 19: ...Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide 9 3 Intel RAID Module RMS2LL0x0 Characteristics Figure 4 Card Layout AF003490 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11...

Страница 20: ...SATA Port 3 J5 SAS SATA Port 4 J6 SAS SATA Port 5 J7 SAS SATA Port 6 J8 SAS SATA Port 7 J5 J8 Ports 4 7 are only available on Intel R RAID Module RMS2LL080 J9 Keyed SGPIO Connector 4 pin keyed connect...

Страница 21: ...Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide 11 Figure 5 RMS2LL040 Hardware Block Diagram...

Страница 22: ...des eight independent PHYs Intel RAID Module RMS2LL040 provides four independent PHYs each supporting 6Gb s and 3Gb s SAS data transfers per PHY Supports SSP to enable communication with other SAS dev...

Страница 23: ...re the server board configures the PCI Express registers The bootstrap ROM sets the Phase Lock Loop PLL dividers bootstrap configuration and so on Diagnostic Components LED Placement and Function The...

Страница 24: ...gnal names are with respect to the host the device connected to the host reverses the signal names Transmit pins connect to receive pins on the other device The SAS SATA connector is keyed at pin 1 Th...

Страница 25: ...15 Table 2 SAS SATA Connector Pin out Figure 9 SAS SATA Cable Pin Signal Description 1 GND Ground 2 TX0 Transmitter differential pair 3 TX0 Transmitter differential pair 4 GND Ground 5 RXD Receiver d...

Страница 26: ...ntel RAID Module RMS2LL040 and RMS2LL080 board interfaces with the host system through a custom board to board interface that implements x8 PCI Express lanes signaling as defined in the PCI Express Sp...

Страница 27: ...RGD_PS_R 3 5 TP_FW_SW_RAID_MODE 4 7 GND 5 9 PE0_TX_DP0 6 11 PE0_TX_DN0 7 13 GND 8 15 GND 9 17 PE0_TX_DP1 10 19 PE0_TX_DN1 11 21 GND 12 23 GND 13 25 PE0_TX_DP2 14 27 PE0_TX_DN2 15 29 GND 16 31 GND 17 3...

Страница 28: ...3 42 34 GND 43 36 GND 44 38 CLK_100M_IOP_DP 45 40 CLK_100M_IOP_D N 46 42 GND 47 44 LED_HDD_ACT_N 48 46 P3V3 49 48 P3V3 50 50 P3V3 Server Connector Pin Number RAID Module Pin number Description Specifi...

Страница 29: ...es 5 inch and 3 5 inch SAS or SATA II drives including SSD drives Non disk devices including expanders Can support drives of mixed capacity Cabling Small thin cables that do not restrict airflow and S...

Страница 30: ...eric characteristics are Relative humidity range 20 to 80 non condensing Maximum dew point temperature 32 C Airflow must be at least 200 linear feet per minute SFPM to avoid operating above the maximu...

Страница 31: ...SAS and enterprise class SATA hard drives Each port supports both SAS and SATA devices using the SAS Serial SCSI Protocol SSP Serial Management Protocol SMP and Serial Tunneling Protocol STP The SSP...

Страница 32: ...ost operating system the RAID firmware typically follows these steps 1 One or more physical drives are selected and associated as an array 2 One or more arrays are associated and given a RAID level Th...

Страница 33: ...ve roaming follow these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server system d...

Страница 34: ...24 Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...

Страница 35: ...help protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests on you...

Страница 36: ...prevent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal...

Страница 37: ...disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis gro...

Страница 38: ...er Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sic...

Страница 39: ...ten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert w...

Страница 40: ...osants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouver...

Страница 41: ...l equipo y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos peri...

Страница 42: ...ema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el m...

Страница 43: ...tro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento del sis...

Страница 44: ...34 Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...

Страница 45: ...rmation Product Safety and EMC Compliance This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For informa...

Страница 46: ...36 Intel RAID Module RMS2LL040 and RMS2LL080 Hardware User s Guide...