80C186EC/188EC, 80L186EC/188EC
AC CharacteristicsÐ80L186EC13
(Continued)
NOTES:
6. See Figure 15 for rise and fall times.
7. T
CHOV1
applies to BHE (RFSH), LOCK and A19:16 only after a HOLD release.
8. T
CHOV2
applies to RD and WR only after a HOLD release.
9. Setup and Hold are required to guarantee recognition.
10. Setup and Hold are required for proper operation.
AC CharacteristicsÐ80L186EC16
(Operating Temperature 0
§
C to 70
§
C)
Symbol
Parameter
Min
Max
Unit
Notes
INPUT CLOCK
16 MHz
T
F
CLKIN Frequency
0
32
MHz
1
T
C
CLKIN Period
31.25
%
ns
1
T
CH
CLKIN High Time
13
%
ns
1, 2
T
CL
CLKIN Low Time
13
%
ns
1, 2
T
CR
CLKIN Rise Time
1
10
ns
1, 3
T
CF
CLKIN Fall Time
1
10
ns
1, 3
OUTPUT CLOCK
T
CD
CLKIN to CLKOUT Delay
0
20
ns
1, 4
T
CLKOUT Period
2
*
TC
ns
1
T
PH
CLKOUT High Time
(T/2)
b
5
(T/2)
a
5
ns
1
T
PL
CLKOUT Low Time
(T/2)
b
5
(T/2)
a
5
ns
1
T
PR
CLKOUT Rise Time
1
9
ns
1, 5
T
PF
CLKOUT Fall Time
1
9
ns
1, 5
OUTPUT DELAYS
T
CHOV1
S2:0, DT/R, BHE, LOCK
3
25
ns
1, 4, 6, 7
T
CHOV2
LCS, UCS, DEN, A19:16, RD, WR, NCS,
3
30
ns
1, 4, 6, 8
WDTOUT, ALE
T
CHOV3
GCS7:0
3
32
ns
1, 4, 6
T
CLOV1
LOCK, RESOUT, HLDA, T0OUT, T1OUT
3
25
ns
1, 4, 6
T
CLOV2
RD, WR, AD15:0 (AD7:0, A15:8), BHE
3
30
ns
1, 4, 6
(RFSH), NCS, INTA, DEN
T
CLOV3
GSC7:0, LCS, UCS
3
32
ns
1, 4, 6
T
CLOV4
S2:0, A19:16
3
34
ns
1, 4, 6
T
CHOF
RD, WR, BHE (RFSH), DT/R, LOCK,
0
28
ns
1
S2:0, A19:16
T
CLOF
DEN, AD15:0 (AD7:0, A15:8)
0
32
ns
1
INPUT REQUIREMENTS
T
CHIS
TEST, NMI, T1IN, T0IN, READY,
15
ns
1, 9
CTS1:0, BCLK1:0, P3.4, P3.5
T
CHIH
TEST, NMI, T1IN, T0IN, READY,
3
ns
1, 9
CTS1:0, BCLK1:0, P3.4, P3.5
T
CLIS
AD15:0 (AD7:0), READY
15
ns
1, 10
T
CLIH
AD15:0 (AD7:0), READY
3
ns
1, 10
T
CLIS
HOLD, RESIN, PEREQ, ERROR, DRQ3:0
15
ns
1, 9
T
CLIH
HOLD, RESIN, PEREQ, ERROR, DRQ3:0
3
ns
1, 9
34