57
Using Local Management
C
H
A
P
T
E
R
5
Local Management
Configure GBIC Ports (470T only)
Description
Port 7- and 8-GBIC: Displays the type of GBIC installed on the switch.
State: Disables or enables ports (press
z
).
Speed/Duplex: The GBIC ports operate at 1000Mbps/full-duplex only;
this is a view-only field.
Flow Control: Enables or disables flow control (press
z
).
Priority: Changes the settings (press
z
). <Frame> reads the
packet’s 802.1 priority tag and handles it accordingly. <Normal> or
<High> forces the packet into one of two priority queues. Forcing a packet
into a queue does not retag the packet.
Link: Indicates the port’s current link status:
--: Indicates no device link or port is disabled.
1000M: Indicates the port’s speed.
Full: Indicates a device is connected at full-duplex.
IEEE/BackP: Indicates the type of flow control, either IEEE PAUSE
frames or backpressure.
Partitioned: Indicates port was disabled due to a partition error.
Source mirror/Target mirror: Indicates the port being mirrored and
where the data is being sent to.
LOCATION
Main Menu
Configure Device
Configure GBIC Ports
Содержание 470F - NetStructure Switch
Страница 1: ...el NetStructure 0 Switch Guide ...
Страница 12: ...6 C H A P T E R 1 Intel NetStructure 470T and 470F Switches User Guide ...
Страница 124: ...118 C H A P T E R 5 Intel NetStructure 470T and 470F Switches User Guide ...
Страница 155: ...A18558 002 ...