background image

34

12Gb/s Intel® RAID Controllers User Guide

hot spare

An idle, powered on, standby drive that is ready for immediate use in case of drive 

failure. A hot spare does not contain any user data. A hot spare can be dedicated to a 

single redundant array or it can be part of the global hot-spare pool for all arrays 

managed by the controller.

When a drive fails, the controller firmware automatically replaces and rebuilds the data 

from the failed drive to the hot spare. Data can be rebuilt only from virtual drives with 

redundancy (RAID levels 1, 5, 6, 10, 50, and 60; not RAID level 0), and the hot spare 

must have sufficient capacity.

I

internal SAS device

A SAS device installed inside the computer cabinet. These devices are connected by 

using a shielded cable.

M

main memory

The part of computer memory that is directly accessible by the CPU (usually 

synonymous with RAM).

N

NVRAM

Acronym for nonvolatile random access memory. An EEPROM (electronically 

erasable read-only memory) chip that stores configuration information. See 

EEPROM

.

P

PCI

Acronym for peripheral component interconnect. A high-performance, local bus 

specification that allows the connection of devices directly to computer memory. The 

PCI Local Bus allows transparent upgrades from 32-bit data path at 33 MHz to 64-bit 

data path at 33 MHz, and from 32-bit data path at 66 MHz to 64-bit data path at 66 

MHz.

PCI Express

Acronym for peripheral component interconnect Express. A high-performance, local 

bus specification that allows the connection of devices directly to computer memory. 

PCI Express is a two-way, serial connection that transfers data on two pairs of point-

to-point data lines. PCI Express goes beyond the PCI specification in that it is intended 

as a unifying I/O architecture for various systems: desktops, workstations, mobile, 

server, communications, and embedded devices.

peripheral devices

A piece of hardware (such as a video monitor, drive, printer, or CD-ROM) used with a 

computer and under the control of the computer. SCSI peripherals are controlled 

through an Intel

®

 RAID Controller (host adapter).

PHY

The interface required to transmit and receive data packets transferred across the 

serial bus.

Each PHY can form one side of the physical link in a connection with a PHY on a 

different SATA device. The physical link contains four wires that form two differential 

signal pairs. One differential pair transmits signals, while the other differential pair 

receives signals. Both differential pairs operate simultaneously and allow concurrent 

data transmission in both the receive and the transmit directions.

R

RAID

Acronym for Redundant Array of Independent Disks (originally Redundant Array of 

Inexpensive Disks). An array (group) of multiple independent drives managed together 

to yield higher reliability, performance, or both exceeding that of a single drive. The 

RAID array appears to the controller as a single storage unit. I/O is expedited because 

several drives can be accessed simultaneously. Redundant RAID levels (RAID levels 

1, 5, 6, 10, 50, and 60) provide data protection.

Содержание 12Gb/s

Страница 1: ...12Gb s Intel RAID Controllers User Guide Intel Order Number H21668 001...

Страница 2: ...UBCONTRACTOR WAS NEGLIGENT IN THE DESIGN MANUFACTURE OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS Intel may make changes to specifications and product descriptions at any time without notice De...

Страница 3: ...of the 12Gb s Intel RAID Controller Chapter 2 provides the instructions on how to install the 12Gb s Intel RAID Controller Chapter 3 describes the characteristics of the 12Gb s Intel RAID Controller G...

Страница 4: ...iv 12Gb s Intel RAID Controllers User Guide...

Страница 5: ...tecture 5 Operating System Support 5 Summary of 12Gb s Intel RAID Controller Characteristics 6 SAS Features 7 SAS Array Limitations 7 SATA III Features 8 PCI Express Performance 9 Usability Features 9...

Страница 6: ...er Guide 12Gb s Intel RAID Controller Characteristics 27 Technical Specifications 28 RAID Controller Specifications 28 Array Performance Features 29 Fault Tolerance 29 Electrical Characteristics 30 Sa...

Страница 7: ...D Controller RS3DC080 Installation in a PCIe Slot 15 Figure 4 Internal SAS Cable for Connection to SAS Drives SATA II Drives or SATA III Drives 17 Figure 5 SATA III Connectors 17 Figure 6 SAS Plugs SA...

Страница 8: ...viii 12Gb s Intel RAID Controllers User Guide...

Страница 9: ...Jumpers and Connectors on the Intel RAID Controller RS3WC080 22 Table 5 Jumpers and Connectors on the Intel RAID Controller RS3DC080 24 Table 6 12Gb s Intel RAID Controller Characteristics 27 Table 7...

Страница 10: ...x 12Gb s Intel RAID Controllers User Guide...

Страница 11: ...rage infrastructure However SAS devices and SATA devices bring individual characteristics that make each one a more suitable choice depending on your storage needs The 12Gb s Intel RAID Controller giv...

Страница 12: ...hich enables communication with other SATA devices Serial Management Protocol SMP which communicates topology management information directly with an attached SAS expander device Serial Tunneling Prot...

Страница 13: ...4i internal connectors Configuration Scenarios You can use the 12Gb s Intel RAID Controllers in three main scenarios Low end internal SATA configuration In this configuration use the RAID controller...

Страница 14: ...igured with an LSISASx12 Expander Benefits of the SAS Interface SAS is a serial point to point enterprise level device interface that leverages the proven SCSI protocol set SAS is a convergence of the...

Страница 15: ...bility with existing ATA firmware PCI Express Architecture PCIe is a local bus system designed to increase data transfers without slowing down the central processing unit CPU You can install the 12Gb...

Страница 16: ...SI3008 LSI3108 LSI3108 PCIe x8 lane width with support for x16 connectors Yes Yes Yes PCIe performance up to 8GT s per lane Yes Yes Yes 1 GB DDR3 1866 MT s onboard SDRAM No Yes Yes Number of Internal...

Страница 17: ...www intel com for specific details about your product They support wide ports that consist of two three or four PHYs within a single quad port They support narrow ports consisting of a single PHY The...

Страница 18: ...LBA which makes it possible to connect a large number of drives to the RAID controller directly and through expanders However the actual number of drives that you can attach depends on the limits list...

Страница 19: ...cabling with point to point serial architecture They support smaller thinner cables that do not restrict airflow They provide drive spin up sequencing control They provide one LED signal for each PHY...

Страница 20: ...entation 3 Move the drives to different positions on the backplane to change the targets 4 Determine the SAS target requirements 5 Perform a safety check a Make sure that the drives are inserted corre...

Страница 21: ...migrate a Make sure that pin 1 on the cable matches pin 1 on the connector b Make sure that the SAS cables conform to all SAS specifications 5 Remove the drives from the first system and insert them i...

Страница 22: ...Data transfer rate Up to 12Gb s per PHY Up to 12Gb s per PHY Bus PCIe 3 0 PCIe 3 0 Cache function Write through non read ahead cache I O direct I O Write back write through non read ahead read ahead...

Страница 23: ...are for experienced computer users or installers Detailed Installation contains the steps for all other users to follow 1 Turn off the power to the system and all drives enclosures and system componen...

Страница 24: ...off the power to the computer and disconnect the AC power cord Remove the computer cover Refer to the system documentation for instructions Before you install the controller make sure that the comput...

Страница 25: ...ation requirements 6 Connect the RAID controller to the devices Use SAS cables to connect SAS devices SATA devices or both to the 12Gb s Intel RAID Controller See SAS Device Cables and Connectors for...

Страница 26: ...motherboard 8 Run the RAID BIOS Console Configuration Utility Run the RAID BIOS Console Configuration Utility to configure the drive groups and the virtual drives When the message Press Ctrl G for RAI...

Страница 27: ...llowing figure shows SAS connectors and SATA connectors on SAS drives and SATA drives respectively Cables connect internal connectors on the RAID controllers to connectors on SAS drives SATA drives or...

Страница 28: ...eps to connect your RAID controller with internal SAS port connectors directly to SAS drives or SATA drives Note The Intel RAID Controller RS3DC080 is shown as an example You can connect the Intel RAI...

Страница 29: ...19 You can connect other devices if the cable has more connectors Figure 7 Connecting the Intel RAID Controller RS3DC080 to a Drive 3_01681 00 Edge of Motherboard PCI Express Slot HDD Connector Power...

Страница 30: ...20 12Gb s Intel RAID Controllers User Guide...

Страница 31: ...sections provide figures and connector information for the 12Gb s Intel RAID Controllers Intel RAID Controller RS3WC080 The Intel RAID Controller RS3WC080 is a low profile SAS SATA RAID controller tha...

Страница 32: ...dge connector J1A SFF 8643 mini SAS HD 4i internal connector x4 SAS Port 0 through Port 3 J1B SFF 8643 mini SAS HD 4i internal connector x4 SAS Port 4 through Port 7 J2 10 pin header Complex programma...

Страница 33: ...Controller RS3DC080 Board Layout and Jumper and Connector Information This subsection provides the board layout and the connector and jumper information for the Intel RAID Controller RS3DC0x0 The foll...

Страница 34: ...cription J1A2 3 pin connector IPMI style I2C connector for Ports 4 to 7 Supports SCSI Enclosure Services SES over I2C through an internal I2C backplane cable J1A3 20 pin connector Local RAID Maintenan...

Страница 35: ...is a single internal port connector J2B4 Standard edge card connector The interface between the RAID controller and the host system Along with the PCIe interface this connector provides power to the b...

Страница 36: ...fault Serial boot ROM SBR header Reserved for use J6B3 2 pin connector Global hard disk drive HDD activity LED header Connects to an LED that indicates activity on the drives connected to the controll...

Страница 37: ...Gb s Intel RAID Controllers use Fusion MPT architecture which allows for thinner drivers and better performance J6B6 6 pin connector Complex programmable logic device CPLD header Reserved for use J6B7...

Страница 38: ...y UL file number E257743 Intel RAID Controller RS3DC040 model 25420 00 Intel RAID Controller RS3DC080 model 25420 00 RAID Controller Specifications The following table lists the specifications for the...

Страница 39: ...el RAID Controller RS3DC0x0 supports the following cache configuration 1 GB 72b arrangement 5 128Mbx16 Double Data Rate III DDR3 1866 MHz with Intel RAID Maintenance Free Backup support Size of flash...

Страница 40: ...etermine the typical current consumption of the controller State 1 During a hard reset State 2 During a drive stress test State 3 While sitting idle at the DOS prompt The supply voltages are 12V 8 per...

Страница 41: ...r the Intel RAID Controller RS3DC0x0 All power is supplied to the Intel RAID Controller RS3DC0x0 through the PCIe 3 3V rails and the 12V rail On board switching regulator circuitry operating from the...

Страница 42: ...ximum ambient temperature Temperature range 10 C to 55 C without battery backup unit Temperature range 10 C to 45 C with battery backup unit The parameters for the nonoperating such as storage and tra...

Страница 43: ...into a single segment of storage space A hot spare drive does not actively participate in a drive group E EEPROM Acronym for Electronically Erasable Programmable Read Only Memory It is a memory chip...

Страница 44: ...Express A high performance local bus specification that allows the connection of devices directly to computer memory PCI Express is a two way serial connection that transfers data on two pairs of poin...

Страница 45: ...l Management Protocol SMP communicates topology management information directly with an attached SAS expander device Each PHY on the controller can function as an SMP initiator SSP Acronym for Serial...

Страница 46: ...36 12Gb s Intel RAID Controllers User Guide...

Отзывы: