background image

Automatic CTCSS tone Scanning

This function allows automatic CTCSS tone scanning on the selected channel. Please
proceed as follows :

1. Select the desired channel number; the CTCSS tone scanning will be activated on this

channel.

2.  Press the ON-OFF/MENU (7) six times, until the CTCSS tone number (F) and the SC Icon

(N) will blink on the LCD display (3).

3. Press the CH UP (4) or the CH DOWN (5) keys to start the automatic CTCSS tone

scanning on the selected channel; the SC Icon (N) will be lighted on the LCD display.
SCAN will automatically stop when a signal is detected on the active channel, in order to
listen to the communication and SCAN will re-start when no more signal is detected on
that channel. 

4. If you press the PTT (15) or LOCK (12) keys during the SCAN operation, SCAN will stop

automatically and radio will set the last used channel. 

Dual Watch Function

The radio is equipped with a Dual Watch function that allows to monitor 2 differents channels
without the CTCSS code. To set the Dual Watch function, please proceed as follows :

1.

Select the first channel to be monitored.

2.  Press the ON-OFF/MENU (7) seven times, until the DW (O) icon and the selected

channel will blink on the LCD display (3).

3.  Press the CH UP (4) or the CH DOWN (5) keys to select the second channel to be

monitored. 

4.

Now the radio will start monitoring the two channels and will stop when a signal is
received on one of the two stored channels.

5.

To disable the Dual Watch function and return to Stand-by mode, press the LOCK
key (12).

Call Tone Setting

The radio is equipped with 5 user selectable Call tone melodies. To set the desired Call tone
melody, please proceed as follows :

1.  Press the ON-OFF/MENU (7) eight times, until the 

C

(B) indication and melody number

(F) will blink on the LCD display (3).

2. 

Press the CH UP (4) or the CH DOWN (5) keys to set the desired melody, between the 5
available melodies.

3.  To confirm the selection and exit the Menu Mode, press LOCK key (12) or press the ON-

OFF/MENU (7) key to move to the next function.

4.

Press the CALL key (6) to transmit the Call Tone Melody.

Roger Beep Tone Setting

The radio is equipped with a user selectable Roger Beep Tone feature, which enables you to
send a Beep Tone at the end of each transmission after every release of the PTT key (15).
This will prompt any receiving unit that your transmission has ended. To enable or disable this
function, please proceed as follows :

1.  Press the ON-OFF/MENU (7) nine times, until the Roger Beep icon (H) and the 

On 

or

OFF 

indications will blink on the LCD display (3).

2.  Press the CH UP (4) or the CH DOWN (5) keys to set the desired selection 

on 

(Roger

Beep tone enabled) or 

oFF 

(Roger Beep tone disabled). If the Roger Beep function is

enabled, a beep tone is heard to confirm the selection.

3.  To confirm the selection and exit the Menu Mode, press LOCK key (12) or press the ON-

OFF/MENU (7) key to move to the next function.

4.

When the Roger Beep tone is enabled, the tone icon (H) appears on the LCD display (3).

Keypad Program Tone Setting

When a key is pressed, a beep tone is heard to confirm your command. The user may enable
or disable this keypad program tone. 

1.  Press the ON-OFF/MENU (7) ten times, until the keypad tone icon (C) and the 

On 

or

OFF 

indications will blink on the LCD display (3).

2.  Press the CH UP (4) or the CH DOWN (5) keys to set the desired selection 

on 

(keypad

tone enabled) or 

oFF 

(keypad tone disabled). If the keypad tone is enabled, a beep tone

is heard to confirm the selection.

3.  To confirm the selection and exit the Menu Mode, press LOCK key (12) or press the ON-

OFF/MENU (7) key to move to the next function.

4.

When the Keypad tone is enabled, the tone icon (C) appears on the LCD display (3).

Stop Watch  function

This function will enable a timer function.
1. Press the ON-OFF/MENU (7) ten times, until the Stop Watch Icon (M) and the 

00:00

indication will blink on the LCD display (3).

2. Press the CH UP key (4) to start counting and press the CH DOWN key (5) to stop the

function. The radio can still operate in this mode.

3. Press the CH UP key (4) again to re-start.

4. To reset the timer press the CH DOWN Key (5) two times.

5. To exit to Stand-by mode press the LOCK Key (12).

With the present declaration, we certify that the following products :

INTEK i-Talk T90

comply with all the technical regulations applicable to the above mentioned products
in accordance with the EC Directives 2006/95/EC, 2004/108/EC, 99/5/EC.

Type of product :

PMR 446 Transceiver

Details of applied standards :

EN 300 296-2, EN 301 489-5, EN 60065

Manufacturer :

INTEK S.R.L.

16 Via G. Marconi
20090 Segrate (Mi)
Tel. 02-26950451 / Fax 02-26952185
E-Mail [email protected]

Contact Reference :

Armando Zanni
Tel. 02-26950451 / Fax 02-26952185
E-Mail [email protected]

Segrate, 10/09/2008

dr. Vittorio Zanetti (General Manager)

DECLARATION OF CONFORMITY

EC Certificate of Conformity

(to EC Directive 2006/95, 2004/108, 99/5)

Notice ! Use of PMR446 Transceivers

This transceiver may be used in all the European countries and in some other countries as
well, according with the regulation of the country where the product is used. 

PMR446 (8 channels) :

Austria, Belgium, Czech Rep., Denmark, Finland, France, Germany,

Greece, Island, Irland, Italy, Luxembourg, Norway, Holland, Poland, Portugal, Spain, Sweden,
Switzerland, UK, Turkey

User Information

in accordance with art. 13 of the Legislative Decree of 25th July 2005, no. 15 ”Implementation
of Directives 2002/95/EC, 2002/96/EC and 2003/108/EC, relative to reduction of the use of
hazardous substances in electrical and electronic equipment, in addition to waste disposal”.

The crossed bin symbol shown on the equipment indicates that at the end of its
working life the product must be collected separately from other waste.
The user must therefore take the above equipment to the appropriate
differentiated collection centres for electronic and electro technical waste, or return
it to the dealer when purchasing a new appliance of equivalent type, in a ratio of
one to one.

Appropriate differentiated waste collection for subsequent recycling, treatment and
environment-friendly disposal of the discarded equipment helps to prevent possible negative
environmental and health effects and encourages recycling of the component materials of the
equipment.

Illegal disposal of the product by the user will be punished by application of the administrative
fines provided for by the legislative decree no. 22/1997 (article 50 and following of the
legislative decree no. 22/1997).

DECLARATION OF CONFORMITY

ADDITIONAL FUNCTIONS

Keypad Lock

To avoid entering unwanted command, press and hold the LOCK Key (12) for about 2
seconds. The Lock Icon (A) will appear on the LCD Display (3). When the keypad is locked,
the PTT (15), CALL (6) and LAMP/MONITOR (11) keys are enabled. To unlock the keypad
press and hold the LOCK key (12) for about 2 seconds.

LCD Backlight

Shortly press the LIGHT/MONITOR key (11) to backlight the LCD display. Press this key again
to turn OFF the LCD backlight.

Monitor Function

Press and hold the LAMP/MONITOR key (11) for about 2 seconds to activate the Monitor
function. This function opens temporary the Squelch in order to listen to the background noise
and weak signals. Press and hold this key for about 4 seconds to activate the Auto Monitor
function in order to activate the Auto Squelch function.
To disable the Auto Monitor function, shortly press the LAMP/MONITOR key (11).

Automatic Power Save

The  radio has a Automatic Power Save circuit designed to extend battery life. If it senses no
transmission within 10 seconds, it automatically switches to the Power Save mode. The
Power Save icon (I) will appear on the LCD display. The Radio can still receive transmissions
in this mode.

SPECIFICATIONS

Channels

8 PMR Channels with 38 CTCSS Codes

Channel Spacing 

12.5 KHz

Operating Frequency 

446.00625 - 446.09375 MHz

Power Source

3.7V (rechargeable Li-Ion battery pack)

RF Output Power 

0.5W ERP

Dimensions

H152 x W60 X D34 mm

Weight

gr. 100 (with battery Pack)

CHANNELS FREQUENCY TABLE

IMPORTANT INFORMATIONS

Important ! 

Changes or modifications to this product could void your authority to operate this unit. Your
radio is produced and factory set to transmit a regulated signal on an assigned frequency. It is
against the law to alter or adjust the settings inside the radio to exceed those limitations. Any
adjustment to your radio must be made by a qualified authorized technician or service.

To be safe and sure :

Never open the cabinet of your radio.
Never change or replace anything in your radio (except the battery).

Your radio might cause TV or radio interference even when it is operating properly. To
determine whether your radio is causing the interference, turn it off. If the interference goes
away, your radio is causing it. Try to eliminate the interference by moving your radio away
from the receiver. If you cannot eliminate the interference, stop using the radio.

Hazardous Environments :

Do not operate the radio in hazardous environments.

Care and Safety :

To clean the radio, use a soft cloth dampened with water. Do not use cleaners or solvents
because they can harm the body of the unit and leak inside, causing permanent damage. Use
a dry, lint-free cloth to clean the battery contacts. 

Do not submerge the unit in water or use

it on a wet environment.

If the unit gets wet, turn it off and remove the battery immediately.

Dry the battery and the battery compartment with a soft cloth to minimize potential water
damage. Leave the battery compartment cover off overnight to ensure complete drying. Do
not use the radio until it is completely dry.

Battery Operation - Important Information

Dispose of battery in the proper manner, according to federal, state and local regulations that
apply in your area. A battery may leak electrolyte if it is mixed in a set with different battery
types, if inserted incorrectly, if disposed of in fire, or if an attempt is made to charge a battery
not intended to be charged. Discard leaky batteries immediately. Leaking batteries can cause
skin burns or other personal injury.

No    Freq. (Hz)

OF  CTCSS OFF

01

67,0

02

71,9

03

74,4

04

77,0

05

79,7

06

82,5

07

85,4

No    Freq. (Hz)

08

88,5

09 91,5 
10

94,8

11

97,4

12

100,0

13

103,5

14

107,2

15

110,9

No    Freq. (Hz)

16

114,8

17

118,8

18

123,0

19 127,3 
20

131,8

21

136,5

22

141,3

23

146,2

No    Freq. (Hz)

24

151,4

25

156,7

26

162,2

27

167,9

28 173,8
29

179,9

30

186,2

31

192,8

No    Freq. (Hz)

32

203,5

33

210,7

34

218,1

35

225,7

36

233,6

37

241,8

38

250,3

-

-

CTCSS - TONE FREQUENCY CHART

FREQ.

CH

FREQ.

CH

FREQ.

CH

446.00625

1

446.01875

2

446.03125

3

446.04375

4

446.05625

5

446.06875

6

446.08125

7

446.09375

8

-

-

Отзывы: