Time of day
When connected to mains supply the display shows 12.00 o’clock and the LED L4
flashes. As long as it is flashing, it is possible to adjust the time via the plus and minus
buttons.
Once the time is adjusted, it is stored approx. 5 seconds after the last operation, the
LED L4 goes dark again.
It is possible to adjust the time-of-day by pressing the mode button until L4 flashes, then
the time-of-day can be adjusted.
Minute minder (interval time)
In order to set the interval time, the “Mode” button has to be pressed repeatedly until
LED L3 is flashing. Then the interval time can be set between 0.01 and 2.30 h by using
the plus and minus buttons. After setting the interval time, it remains displayed and the
LED L3 is now illuminated steadily. After th interval time has run down, the alarm signal
sounds (2 beeps every 2 seconds) and the LED L3 is flashing again. Pressing any of the
buttons stops the signal and the flashing, the LED goes dark and the display reverts to
the time-of-day. If the alarm is not stopped manually, it terminates automatically after
2 minutes.
The minute minder can be applied at any time while other functions are operative.
Operation period
In order to set an operation period, the mode button has to be pressed repeatedly
until the LED L1 is flashing. Then the desired operation period (time frame between
0.01h and 10.00h) can be set using the plus and minus buttons. Once adjusted, it will
be stored after approx.. 5 seconds, the LED L1 remains illuminated steadily, and the set
time starts running down. The display reverts to the time-of-day. As soon as the
operation period has ended, the relay opens and the alarm signal sounds (4 beeps
every 2 seconds) and the LED L1 is flashing again. Pressing any of the buttons stops the
signal and the flashing, the LED goes dark and the relay closes again. If the alarm is
not stopped manually, it terminates automatically after 2 minutes.
Operation stop
In order to set an operation stop, the mode button has to be pressed repeatedly until
the LED L2 is flashing. Then the desired operation stop, which is limited to a ponit being
maximally 23.59 h in the future, can be set using the plus and minus buttons. Once
adjusted it will be stored after approx. 5 seconds, and the LED L2 remains illuminated
steadily. The display reverts to the time-of-day. As soon as the operation stop has been
reached, the relay opens and the alarm signal sounds (4 beeps for 2 minutes) and the
LED L2 is flashing. Pressing any of the buttons stops the signal and the flashing, the LED
goes dark and the relay closes again.