FEATHERWEIGHT BIRD SCALE rev.01
1. INTRODUCTION
1.1 PRECAUTIONS, CARE & MAINTENANCE
WARNING:
Read and save
these instructions!
Safety may be jeopardized if the equipment is used in a manner not
specified by the manufacturer. Carefully read and keep the following
instructions for future reference.
•
Although fuses at the input and outputs of the controller protect its
circuits in case of an overload or overvoltage, we recommend
installing an additional protection device on the controller's supply
circuit.
•
The room temperature where the controller is located must always
remain between 32 °F and 104 °F (0 °C to 40 °C). For Indoor use
only !
•
To avoid exposing the controller to harmful gases or excessive
humidity, it is preferable to install it in a corridor.
•
Do not spray water on the controller! In order to clean the control,
wipe it with a damp cloth.
Before servicing or cleaning unit, switch power off at service
panel and lock the switch disconnecting means to prevent power
from being switched accidentally. When the service disconnect-
ing means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
•
The controller should be opened and inspected once a year for
moisture. Proper care will extend the life of the control.
25
FEATHERWEIGHT BIRD SCALE rev.01
6. TECHNICAL SPECIFICATIONS
Type
FEATHERWEIGHT
Main supply fuse F1
1A, fast-blow
Mains supply/frequency
115/230V±10%, 50/60Hz
Precision on variable outputs
±1 %
14Vdc output
14 Vdc ±10%, regulated, 100mA
max.
14Vdc output fuse F2
1A, fast-blow
Housing
IP54, plastic casing
Operating temperature
0 to 40°C (32 to 104°F)
Storage temperature
-15 to 50°C (32 to 104°F)
Ambient relative humidity
max. 95%
Pollution degree
2
Altitude
Up to 2000m
Installation Category:
Class II
The room temperature where the controller is located must always
remain between 32
o
and 104
o
F (0
o
and 40
o
C).
For indoor use only.