INSTALLATION AND MAINTENANCE 

INSTRUCTIONS  

A COPY OF THESE INSTRUCTIONS SHOULD BE LEFT WITH THE EQUIPMENT UNTIL

INSTALLATION BY ALL TRADES IS FULLY COMPLETE.  FOLLOWING FINAL 

INSPECTION, A COPY SHOULD BE LEFT WITH THE OWNER/USER.

 

SM-501-N 

Ionization Type, 4-Wire Duct Smoke Detector

 SM-501-P 

Photoelectric Type, 4-Wire Duct Smoke Detector

MSR- SERIES REMOTE ACCESSORIES

Visual Indicators: Alarm, Pilot, Trouble

Buzzer: Programmable for Alarm and Trouble

Buzzer Silence: Visual Notification and Ringback

Detector Test/Reset: Key Operated
LED/Buzzer Test:  Push-Button  Operated

MSR-100R/W  

White Face Plate

MSR-100R/R  

Red Face Plate

MSR-100R/S  

Stainless Steel Face Plate

MSR-100RS/W/C  

White Face Plate; Strobe with Clear Lens

MSR-100RS/W/O 

White Face Plate; Strobe with Opaque Lens

MSR-100RS/R/C  

Red Face Plate; Strobe with Clear Lens

MSR-100RS/R/O 

Red Face Plate; Strobe with Opaque Lens

MSR-100RS/S/C  

Stainless S t eel Face Plate; Strobe with Clear Lens

MSR-100RS/S/O  

Stainless Steel Face Plate; Strobe with Opaque Lens

MS- and SHP- SERIES REMOTE ACCESSORIES

MS-RA  

Remote Alarm

MS-RA/R  

Remote Alarm, push button Test/Reset Switch

MS-RA/P/R  

Remote Alarm, Pilot, push-button Test/Reset Switch

MS-KA/R  

Remote Alarm,  key-operated Test/Switch

MS-KA/P/R  

Remote Alarm, Pilot, key-operated Test/Reset Switch

MS-RA/P  

Remote Alarm, Pilot

MS-RH  

Remote Alarm Horn

MS-RH/KA/P/R  

Remote Alarm, Pilot, Horn, key-operated Test/Reset Switch

MS-RH/P/A  

Remote Alarm, Pilot, Horn

MS-RH/KA/P/A/T 

Remote Alarm, Trouble, Pilot, Horn, key-operated Test/Reset Switch

MS-RA/P/T  

Remote  Pilot, Trouble

MS-RA/FT/P  

Remote Pilot, Trouble, push-button Test/Reset Switch

MS-KA/P/R/T  

Remote Pilot, Trouble, key-operated Test/Reset Switch

MS-RD  

Remote Alarm

MS-F/T  

Remote Trouble

SMOKE TEST  GAS

TG-1000  Solo Aerosol Test  Gas

SAMPLING TUBES

STS-1.0 

For duct widths of 6” TO 1.0’

STS-2.5 

For duct widths of 1.0’ TO 3.0’

STS-5.0 

For duct widths of 3.0’ TO 5.0’

STS-10.0  

For duct widths of 5.0’ TO 10.0’

FAST Tube 

Sectional Tube for use in ducts up to 8ft wide

WEATHERPROOF ENCLOSURES

WP-1 Weatherproof  Enclosure

REPLACEMENT SMOKE DETECTOR HEADS

55000-225 

S65 Ionization Detector Replacement Head

55000-328 

S65 Photoelectric Detector Replacement Head

POWER SUPPLIES

T-PB 202-1 

24VAC @ 4.0A Class I Power Supply

T-PB 202-0 

24VAC @ 4.0A Class I Power Supply

T-PB 303-1 

24VAC @ 3.0A Class II Power Supply

T-PB 303-0 

24VAC @ 3.0A Class II Power Supply

NOTICE:

 The information contained in this document is the most current available at the time of shipment of accompanying product, and is subject to 

change without notice.  Future references should always be made to the most current revision of this document.  The information contained in all this 

document should be considered before installing or using the product. Any example applications shown are subject to the most current enforced local/
national codes, standards, approvals, certifications, and/or the authority having jurisdiction.  All of these resources, as well as the specific manufacturer 
of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning this 
product, contact us. Specifications subject to change any and all documentation without notice.

SM-501 SERIES

DUCT SMOKE DETECTORS

AVAILABLE ACCESSORIES FOR USE WITH

SM-501 SERIES DUCT SMOKE DETECTORS

Specifications subject to change without notice. | INST APD0191 D140113 | USA 150303 | Page 1 of 7

12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN

TEC

 | relevantsolutions.com/inteccontrols

SM-501 – Installation

Содержание SM-501 Series

Страница 1: ...ned in all this document should be considered before installing or using the product Any example applications shown are subject to the most current enforced local national codes standards approvals ce...

Страница 2: ...e air stream reach the alarm threshold of the detector head the unit will go into alarm The duct smoke detector units are designed to operate in duct widths from 6 to 10 wide with an air velocity betw...

Страница 3: ...10 0 For duct widths of 5 0 to 10 0 FAST TUBE Sectional Tube for duct widths up to 8 0 Standard sampling tubes are steel tubes with air intake holes drilled the entire length of the tube FAST Tubes ar...

Страница 4: ...A MAX 115VAC INPUT Terminals 1 2 3 230VAC 50 60 Hz 0 1A MAX 230VAC INPUT Terminals 1 2 4 24VDC OPERATION 115VAC OPERATION 230VAC OPERATION G H1 H2 24VAC OPERATION WIRING CAUTION For terminals 7 15 do...

Страница 5: ...tector X SM 501 Detector 1 11 15 12 INTERCONNECTION WIRING FOR COMMON FUNCTIONS MS REMOTE ACCESSORY WIRING C TB P C AL T R 18 20 21 17 19 14 JUMPER A jumper wire must be placed between Terminals 14 an...

Страница 6: ...e alarm relays will change state and the alarm related remote accessories if attached will function If no test gas is available to conduct functional testing light a piece of clothesline rope and blow...

Страница 7: ...itch MS RH P A Remote Alarm Pilot Horn MS RH KA P A T Remote Alarm Trouble Pilot Horn key operated Test Reset Switch MS RA P T Remote Pilot Trouble MS RA FT P Remote Pilot Trouble push button Test Res...

Отзывы: