Instruction Manual
|
7
T: 303-833-6644
or
800-666-1611
www.inteccorp.com
Original Language - English
Backflow preventers:
The backflow preventers (or one-way valves) are found in the base of the
system positioned between the blower and airlock. The backflow preventers will keep insulation from
flowing backwards through the airlock and into the blower which may happen when the pressure of
product in the hose is more than that of the pressure in the line between the blower and airlock -
examples include (i) hose moving straight up from machine to a second or third story, or (ii) during
some dense pack operation. The back blow preventer prolongs the blower motor
’s
life.
Control Panel
Agitator Motor
Primary Blower
Backflow Preventers
Airlock
Airlock Drive Sprocket
Gearbox
Secondary Blower
Self-Adjusting Chain Tensioner