Intec Force 1 Скачать руководство пользователя страница 53

W

ARRANTY

48

THE FORCE/1

Warranty

It is expressly understood and agreed that no officer, agent, salesman or employee 
of the Manufacturer INTEC has the authority to obligate the Manufacturer by any terms,
stipulations, or conditions not herein expressed; that all previous representations and
agreements, either verbal or written, referring to the machinery and equipment, which is the
subject of this Warranty, are hereby superseded and 
canceled, and that there are no promises or agreements outside of this Warranty agreement.
Furthermore, the Manufacturer hereby disclaims any implied warranties of merchantability,
or implied warranties of fitness for a particular purpose.

With the above understanding, the Manufacturer’s FORCE/1 insulation blowing machine is
sold with the following one (1) year Limited Warranty, and no other:

a) Manufacturer warrants to the original purchaser that the machine is well made, 
of good material and durable; but only if the machine is operated and maintained 
in accordance with this Operator’s Manual and the Maintenance Manual. This Warranty is
void if the machine is not so operated and maintained, or if the machine is used for blowing
materials other than those which are intended to be used with 
the machine.

b) Manufacturer guarantees the machine to be free from manufacturing defects at the time
of shipment, and to remain free from defects when operated under normal use, for a period
of one (1) year from the date of factory shipment, with the 
exception of the blower, electrical and air lock components, which are guaranteed 
for a period of ninety, (90) days from date of factory shipment.

c) This Warranty shall not apply to any machine or component part which, in the opinion
of the Manufacture, has been altered, subject to misuse, negligence, 
accident or operated beyond factory rated capacity. All requested Warranty work shall be
performed at Manufacturer’s factory or by an Authorized Factory Service Facility. Failure to
have the Warranty work done at Manufacturer’s factory or by an Authorized Factory Service
Facility will void this Warranty. Manufacturer will bear full responsibility to repair or replace,
at its option, without charge to the original 
purchaser, any part which, in the Manufacturer’s opinion, is found to be defective.

d) All parts claimed defective by original purchaser shall be returned, properly 
identified, to Manufacturer’s factory or Authorized Factory Service facility, freight prepaid. All
replacement, repaired or non-defective parts will be returned to 
purchaser, freight collect. Manufacturer will supply replacement parts prior to 
receipt of my parts claimed defective, only with the understanding that such 
replacement parts will be shipped to purchaser at the then prevailing price of said part,
C.O.D., freight collect. Manufacturer will reimburse cost of any such part only after receipt
and inspection, and finding said part defective.

e) Manufacturer’s liability is expressly limited to the repair or replacement of 
defective parts set forth in this Warranty. All other damages and warranties, 
statutory or otherwise, being waived by original purchaser as a condition of sale and
purchase of said machines. Furthermore, the Manufacturer shall not be liable for damages
or delays caused by defective material or workmanship.

This Warranty is effective only for the original purchaser and is not transferable.

W

ARRANTY

Содержание Force 1

Страница 1: ...Instruction Manual 3771 Monarch Street Frederick CO 80530 www inteccorp com Local 303 833 6644 Fax 303 833 6650 Toll Free 800 666 1611...

Страница 2: ...ks Together 10 Safety First 11 Set Up Operation 12 Operational Guidelines 16 Sidewalls Insulation Material 18 Generators and Extension Cords 20 Maintenance 21 Troubleshooting 29 Mechanical Drawings 33...

Страница 3: ...MACHINE INFORMATION 2...

Страница 4: ...of Intec Consult the nearest service center for the hours of operation and lead time for repair Website support Visit our web site 24 7 at www inteccorp com and go to the specific model your wanting i...

Страница 5: ...CE 1 Because no insulation actually goes through the blower the FORCE 1 is a virtual workhorse requiring only minimal maintenance and almost no downtime The direct drive feature also means there are n...

Страница 6: ...tor Motor 3 4 hp 9 5 amps 115 VAC Gearbox Custom direct drive Airlock 6 1 2 x 7 1 4 opening steel 6 vane cast urethane seals Electric 115V 20 amp 50 60Hz 220V 10 amp 50 60Hz optional Agitator 3 vane W...

Страница 7: ...metal sleeve ELECTRICAL COMPONENTS Your FORCE 1 requires a dedicated 20 amp grounded power supply Less amperage will likely trip circuit breakers Always disconnect the power source before beginning an...

Страница 8: ...THE FORCE 1 Overview OVERVIEW 7 OVERVIEW Example only see page 43 for specific electrical systems...

Страница 9: ...8 THE FORCE 1 Overview OVERVIEW...

Страница 10: ...9 Remote Switch THE FORCE 1 Overview OVERVIEW Remote Cord Power Cord Agitator Switch Blower Switch Agitator...

Страница 11: ...airflow which propels the material from the airlock into the hose for distribution No insulation material passes through the blower The blower moves 104 CFM drawing eight amps 115 VAC See the mainten...

Страница 12: ...achine unattended while it is running Turn off and disconnect power before taking a break Never operate your machine if it or the operator is standing in water Serious injury may result When working w...

Страница 13: ...temporarily unplugged enabling the FORCE 1 to use the outlet Disconnecting these appliances for the short time needed to operate the FORCE 1 will not cause spoilage Remember to reconnect any unplugge...

Страница 14: ...o two inch diameter HOPPER SAFETY Your safety is the most important consideration whenever you are using any machine Following the instructions in this manual along with good common sense should allow...

Страница 15: ...t the end of each job Do not put your hands inside the hopper while the machine is running If a tool or other foreign object accidentally falls into the hopper turn the machine off immediately Careles...

Страница 16: ...according to the distribution rate Empty no more than 1 3 bag at a time into the hopper waiting until at least 1 4 of the material has been used before adding additional insulation Forcing insulation...

Страница 17: ...material or nozzle to nozzle Hose length and humidity may also affect your results Two hole method standard wall construction 2 x 4 x 16 on center Hole size Slide gate opening Air Setting 2 61 2 100...

Страница 18: ...he wall cavity Turn blower switch on first then the agitator When the sidewall is full the FORCE 1 blower will rev up trying to work harder and material flow may stop Turning off first the agitator th...

Страница 19: ..._______________________ CertainTeed Technical Services 800 233 8990 CertainTeed InsulSafe SP 31 pound bag Wall Pack Density Pounds Per Cavity 1 80 pounds 5 04 pounds Average yield with InsulSafe SP 6...

Страница 20: ...mple 1 31 2 deep x 141 2 wide x 925 8 tall 4 700 cubic inches 2 Divide 4 700 by 1 728 2 72 cubic feet in the cavity Each wall cavity may vary slightly 1 728 equals the number of cubic inches in a cubi...

Страница 21: ...generator of not less than 4000 watts 115 VAC In addition Intec recommends generators that have a 50 power boost feature which aids the generator in high current startups Running additional equipment...

Страница 22: ...ing pressure and air from escaping When a seal or plate is damaged air from the blower will escape back into the hopper causing blow back Blow back will result in a considerable decrease in production...

Страница 23: ...ched to the shaft Reverse the process to install a new seal Be careful that the direction of the seal is correct When it is equally wrapped around both sides and seated all the way down on the rotor s...

Страница 24: ...ise See figure 2 REPLACING ROTOR PLATE The rotor plates are designed to give if a foreign object comes in contact with the airlock chamber but they can be bent Before replacement disconnect the machin...

Страница 25: ...16 open end wrench With the machine in an upright position locate the four 1 4 20 bolts that secure the seal Loosen and remove the fasteners and the seal from the front rotor plate Locate the gold bo...

Страница 26: ...ine in a warm area overnight eight hours to make oil changing easier See illustration for the location of the drain fill plugs Models manufactured before July 1997 require 24 ounces of oil 12 in each...

Страница 27: ...and remove using a 5 16 hex wrench Drain oil into pan tip machine upright to drain remainder of oil in gearbox housing close vent plug Pour 48 ounces into worm gear case and re install drain plug Tip...

Страница 28: ...l otherwise all other covers may be pried off using screwdriver By hand carefully turn fan blade in the direction of the arrow as indicated on label until jam is cleared Note It will take approximatel...

Страница 29: ...ling the lead wires must be isolated from the motor frame and any rotating parts CLEANING Use compressed air to blow out motor and intake of blower every 20 30 hours of use to maximize blower impeller...

Страница 30: ...m and remove material with pliers Jam between blade of Disconnect agitator and airlock electrical power Remove insulation material from hopper Locate jam and remove material with pliers Bearing on top...

Страница 31: ...ls Inspect seals for throw tears or cuts See maintenance section to replace or adjust as necessary Kink in hose Run hose as straight as possible to help maintain production Excess air leaking into Ins...

Страница 32: ...lade of Disconnect electrical agitator and airlock power Remove insulation material from hopper Locate jam and remove material with pliers Blower does not operate Blower toggle switch on Switch toggle...

Страница 33: ...ional 50 run use 12 3 cord For a 100 run use 10 3 cord Do not push down on insulation while filling hopper Do not use wet material Disconnect electrical power and remove wet material Have bearing chec...

Страница 34: ...ssembly 12002 Blower Intake Gearbox 12007 12008 Airlock Inlet Plate Assm 12014 12021 Airlock Outlet Plate Assm 12016 12022 Airlock Tube 12012 21 2 Hose 22050 Airlock Rotor Shaft Airlock Rotor Plates l...

Страница 35: ...23 22000 04 SLIDE GATE CABLE PIN Manufactured from 9 03 Present 24 22000 06 SLIDE GATE GUIDE RIGHT 25 22000 07 SLIDE GATE GUIDE LEFT 26 22022 BLOWER MOUNT BRACKET 27 22025 05 AGITATOR MOTOR ROTATION L...

Страница 36: ...COLLAR 5 8 21 12270 SERIAL TAG F 1 22 12274 HANDLE SS 3 4 x 14 23 22000 04 SLIDE GATE CABLE PIN 24 22000 06 SLIDE GATE GUIDE RIGHT 25 22000 07 SLIDE GATE GUIDE LEFT 26 22022 BLOWER MOUNT BRACKET 27 2...

Страница 37: ...PLATE ASSM 2 1 2 4 12018 AIRLOCK BEARING END PLATE 5 12019 S AIRLOCK ROTOR ASSM W SEALS 6 F112 1 4 20 x 7 8 HEX ZN 7 F115 1 4 SPLIT LOCK WASHER ZN 8 12024 AIRLOCK SS INSERT 2 9 12023 0 AIRLOCK SS INSE...

Страница 38: ...PART NUMBER DESCRIPTION 1 12012 AIRLOCK TUBE 10 2 12021 AIRLOCK INLET PLATE ASSM 2 3 12022 AIRLOCK OUTLET PLATE ASSM 2 1 2 4 12018 AIRLOCK BEARING END PLATE 5 12020 01 S AIRLOCK ROTOR ASSM W SEALS 6 F...

Страница 39: ...MBER DESCRIPTION 1 12002 01 BLOWER 115V 104 CFM 2 12101 BLOWER ISOLATION MOUNT 3 F115 1 4 SPLIT LOCK WASHER 4 F114 1 4 20 NYLON LOCK NUT 5 F342 1 4 20 X 3 4 BOLT 6 F159 1 4 FLAT WASHER 7 22022 BLOWER...

Страница 40: ...1008 06 01 S REMOTE BOX ROCKER SWITCH ASSM 27 RR21004 REMOTE BOX 3 4 SHIELD W O STICKER 28 F119 8 32 x 3 8 PP ZN 29 F122 6 32 x 3 8 PP ZN 30 F124 6 32 NYLON INSERT LOCK NUT 31 F153 6 RING TERMINAL BLU...

Страница 41: ...SM 14 3 x 50 3 11065 ELEC FACE PLATE W SILK SCR 4 11067 CIRCUIT BREAKER 15 AMP 5 11071 TOGGLE SWITCH 20 AMP 6 11072 TOGGLE SWITCH SEAL 7 21008 02 STRAIN RELIEF ALUM 1 2 8 21045 02 CIRCUIT BREAKER BUTT...

Страница 42: ...ELECTRICAL DRAWINGS 41 Electrical Wiring Diagram Electrical With Relay Mfg from 10 02 Present...

Страница 43: ...LK SCR 4 11067 CIRCUIT BREAKER 15 AMP 5 11071 TOGGLE SWITCH 20 AMP 6 11072 TOGGLE SWITCH SEAL 7 21008 02 STRAIN RELIEF ALUM 1 2 8 21045 02 CIRCUIT BREAKER BUTTON SEAL 9 31044 KBGE 25 AMP 120 VAC 10 21...

Страница 44: ...ELECTRICAL DRAWINGS 43 Electrical Wiring Diagram Electrical With Relay VS Control Mfg from 7 02 Present...

Страница 45: ......

Страница 46: ...RN GRN RED RED RED REMOTE CORD AGIT TOGGLE SWITCH 20 AMP 15 AMP CIRCUIT BREAKER ELECTRICAL PANEL 1 0 8 4 6 2 RELAY T92P7A22 120 MOUNTED TO THE BASE UNDER ELECTRICAL PANEL BLOWER TOGGLE SWITCH 20 AMP B...

Страница 47: ...the machine FIRST TURN ON THE BLOWER then the agitator When shutting the machine off FIRST TURN OFF THE AGITATOR then the blower NOTE Do not allow the agitator to run for more than 5 minutes without t...

Страница 48: ......

Страница 49: ...l damage When the damage is discovered upon unpacking make a written request for inspection by the carrier s agent within ten days of the delivery date Then file a claim with the carrier since such a...

Страница 50: ...using their web address www ups com using custserv to notify them of the damaged package Fill out the information sheet on the following page and mail or fax it to the attention of the Shipping Depar...

Страница 51: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 52: ...30 days after issue date Shipments beyond the 30 day expiration may not be credited We will repair or replace at our option any returned part found to be defective in materials or workmanship under t...

Страница 53: ...s from date of factory shipment c This Warranty shall not apply to any machine or component part which in the opinion of the Manufacture has been altered subject to misuse negligence accident or opera...

Страница 54: ...ower reduces dust when blowing insulation into an attic The FORCE 1 features the lowest CFM of all insulation blowing machines minimizing the dust problem You ll be able to see what you are doing PSI...

Страница 55: ...r Space 1 1 01 Cellulose loose fill 1 3 70 Celotex 1 3 03 Concrete block 8 hollow 1 11 Fiberglass batt 31 2 11 0 Fiberglass batt 8 19 0 Fiberglass loose fill 1 2 2 Rockwool batt 3 4 11 0 Rockwool batt...