background image

ENGLISH

 

 

 

Quick Installation Guide 

MRX LTE 

 

Mat. no. 10017059 – version 27 July 2017 11:34:47 – Subject to technical changes and correction 

www.insys-icom.com 

 

IP address in configuration network 

 

The IP address of the router in the configuration network does only have to be changed, 
if the IP address is already used or a different address range is required. Then, the web 
interface is immediately accessible under the new address. 

1. 

Menu Interfaces > IP net 1: Adjust IP address of the router in configuration network 

2. 

Store settings in profile with 

Save settings

 and activate profile with

 

3. 

Adjust IP settings of the PC for further configuration accordingly, if these are not 
obtained automatically (see step B) 

4. 

Menu Services > DHCP Server: Adjust address range to the configuration network, if 
the DHCP server of the router is used 

 

 

Resetting the router 

 

If it is necessary to reset the router during configuration, this is possible without losing 
the settings. 

1. 

Menu Administration > Reset:  

2. 

Click on 

Reboot device now

 

 

Alternatively, press reset key on the device front once for a short time (soft reset) 

Resetting the router to default settings 

 

If the router is to be reset to default settings, it can be reset to delivery state. 

1. 

Menu Administration > Reset: check all options 

2. 

Click on 

Reset now

 

 

Alternatively, press reset key on the device front three times for a short time within 
2 seconds 

Resetting and initialising the router 

 

If the router is not available any more for any reason, it can be reset and initialised 
(settings do not get lost). 

1. 

Press reset key on the device front for at least 3 seconds (hard reset) 

 

 

Configuration Guides and manuals for integrating your product into your 
application are available in the menu Support and Downloads  
http://www.insys-icom.com/support 

 

 

For interesting information about your product refer to our website in the menu 
Knowledge Base  
http://www.insys-icom.com/knowledge 

 

Hereby, INSYS Microelectronics GmbH declares that herein described device types are in compliance with Directives 2014/53/EU 
and 2011/65/EU. The full text of the EC Declaration of Conformity is available under www.insys-icom.com/manual. 

Содержание MRX3 LTE

Страница 1: ...on in machines or systems in explosive atmospheres Controlling switching and data transmission of machines which may involve risks to life and limb due to their functions or when a breakdown occurs Technical Boundaries Max line length for antennas power supplies serial interfaces inputs and outputs as well as other signals 30 m Max line length of USB connection lines 3 m Cable cross section 0 25 1...

Страница 2: ...4 TCP IP and Properties Enable DHCP client 9 Obtain an IP address automatically It is recommended to unplug the network cable briefly and plug it again upon activation of the DHCP client Configure a static IP address Use the following IP address example IP address 192 168 1 2 Subnet mask 255 255 255 0 Standard gateway 192 168 1 1 Preferred DNS server 192 168 1 1 Please note the previous values bef...

Страница 3: ...mer name and Device code Then the IP address in the local network will be assigned by the icom Connectivity Suite VPN The WAN LED flashes green during connection establishment as soon as an Internet connection has been established it is illuminated green and the Signal LED flashes orange E Configuration of access data User name and password for web interface access of the existing user in the defa...

Страница 4: ...ation Reset 2 Click on Reboot device now Alternatively press reset key on the device front once for a short time soft reset Resetting the router to default settings If the router is to be reset to default settings it can be reset to delivery state 1 Menu Administration Reset check all options 2 Click on Reset now Alternatively press reset key on the device front three times for a short time within...

Отзывы: