![insys icom i-modul 336 LL Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/insys-icom/i-modul-336-ll/i-modul-336-ll_designers-manual_2070365053.webp)
i-modul Modem 336 LL
S Registers
S5
Backspace
character
Backspace character
S6*
Waiting period dial tone
Maximum waiting time for the dialing tone. After the modem went off-hook it
waits 7 seconds for the dialing tone (fixed for approval purposes). If it detects a
dialing tone during this waiting period it will start dialing.
If it does not detect a dial tone, it will check if the dial tone recognition is activated
or if the dialing string (Chapter "
AT
command set", command
ATD
) contains the
parameter
W
. If the dialing tone detection is not activated, the modem waits for
the dialing tone. The waiting time (in seconds) is specified in S6.
The value of the S6 register can be between 4 and 7 seconds.
S7*
Waiting period carrier signal
Wait for the carrier frequency from the other modem. The maximum time for the
modem to wait for a response from the other modem is specified in S7. The time
starts running as soon as the modem has finished dialing. The value of S7 can be
between 0 and 180 seconds. Default values are 50 (Originate) and 30 (Answer).
S8*
Dial tone delay
Dial pause time, if a comma is included in the dialing string. If there is a comma in
the dialing string, the modem will wait during the dialing procedure, until the
time specified in S8 (in seconds) has run out. The value of S8 can be between 1
and 7 seconds.
S9*
Reaction time carrier signal
DCD response time for the carrier frequency from the other modem. The DCD
output of the RS232 interface (CT109) of the modem switches to ON, when the
carrier frequency from the other modem is detected before the time defined in S9
(in tenth of seconds) runs out. S9 must be smaller than S10.
S10*
Time period between lost carrier signal and hang up
The time which leads to termination after carrier frequency loss. In S10, the time
period for which the modem waits for the disconnection if it can no longer detect
the carrier frequency from the other modem, is specified in tenth of seconds.
S11*
Operation
mode
S11=1
Answer / 2 wire mode
S11=3
Originate / 2 wire mode
S11=5
Answer / 4 wire mode
S13=7
Originate / 4 wire mode
Note: After changing the value set the S7 register as well. The default values are 3
(Originate) and 1 (Answer).