![Instruo ceis Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/instruo/ceis/ceis_user-manual_2070214013.webp)
13
Control Path:
•
Connect the 1V/Oct output of a sequencer or keyboard to the 1V/
Oct input of the oscillator.
•
Connect the gate output of the sequencer or keyboard to the
Gate/
Trig input
of
cèis.
•
Connect
CV Output
of
cèis
to a multiple.
•
Connect one copy of the
cèis
CV signal to the cutoff frequency
CV input of the filter and set the corresponding CV attenuator to a
desired position.
•
Connect a second copy of the
cèis
CV signal to the CV input of the
VCA and set the corresponding CV attenuator to a desired position.
•
Set the
Shape
knob its maximum setting for a logarithmic/
exponential response curve.
•
Set the
Attack
,
Decay
,
Sustain
,
and
Release
settings to a
desired position.
Содержание ceis