![INSTEON LampLinc 2456D3 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/insteon/lamplinc-2456d3/lamplinc-2456d3_manual_2069948009.webp)
LampLinc Owner’s Manual
X10 PROGRAMMING OPTIONS
LampLinc is X10 ready, meaning that it can respond to X10 commands from X10 controllers. However, to operate
LampLinc in X10 mode, you must first set up an X10 address. As it ships from the factory or after a factory reset
procedure, LampLinc will not have an X10 address set up.
Setting the X10 Primary Address
1) Set LampLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The LampLinc Status LED should begin blinking
The load should flash once
You will have 4 minutes to complete the next step before Linking Mode automatically times out.
2) Using an X10 controller, send the X10 address you want to assign and the ON command
three times
For example, to assign the address A1, you would send “A1 ON A1 ON A1 ON.”
3) Once LampLinc has received the sequence, it should exit Linking Mode
The LampLinc Status LED should flash twice and then turn on solid
The load should flash twice
Removing the X10 Primary Address
If you are no longer going to control LampLinc with an X10 address, it is very important that you Unlink it. Otherwise,
LampLinc will still respond to X10 commands and may cause LampLinc to turn on by itself.
1) Set LampLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The LampLinc Status LED should begin blinking
The load should flash once
2) Set LampLinc to Unlinking Mode by pressing & holding the Set button for 3 seconds
The LampLinc Status LED should continue blinking
The load should flash once
You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.
3) Using an X10 controller, send the X10 address you wish to remove and the ON command
three times
For example, to remove the address A1, you would send “A1 ON A1 ON A1 ON”.
4) Once LampLinc has received the sequence, it should exit Linking Mode
The LampLinc Status LED should flash twice and then turn on solid
The load should flash twice
Setting the X10 On-Level and X10 Ramp Rate for the X10 Primary Address
When an X10 controller sends an X10 ON or X10 OFF command to LampLinc’s Primary Address, the local On-Level
and Ramp Rate apply. In other words, LampLinc should act the same way as it would if you manually tapped the
switch.
See
Setting the On-Level
or
Setting the Ramp Rate
for instructions on setting up the local On-Level and Ramp Rate
NOTE: If you want an X10 On-Level or Ramp Rate other than the local values, you can set up one or more X10
scene addresses as described in
Remotely Setting the On-Level for an X10 Scene Address
and
Remotely Setting the
Ramp Rate for the X10 Scene Address.
Enabling/Disabling X10 Resume Dim
If X10 Resume Dim is enabled, LampLinc will remember the last brightness level to which it was set. Then, when an
X10 ON command is received from an X10 controller, the load will go to the remembered brightness, rather than to
the X10 On-Level.
To enable X10 Resume Dim, set up a local On-Level of off (or zero). To disable X10 Resume Dime, set up a local
On-Level of anything but off. See
Setting the On-Level
for instructions on setting up the local On-Level.
Page 9 of 14