ApplianceLinc Owner’s Manual
Page 8 of 12
X10 PROGRAMMING OPTIONS
ApplianceLinc is X10 ready, meaning that it can respond to X10 commands from X10 controllers.
However, to operate ApplianceLinc in X10 mode, you must first set up an X10 Primary Address. As it
ships from the factory or after a factory reset procedure, ApplianceLinc will not have an X10 Primary
Address set up.
Setting the X10 Primary Address
1) Set ApplianceLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The ApplianceLinc Status LED will begin blinking
You will have 4 minutes to complete the next step before Linking Mode automatically times out.
2) Using an X10 controller, send the X10 address you want to assign and the ON command
three times
For example, to assign the address A1, you would send “A1 ON A1 ON A1 ON.”
3) Once ApplianceLinc has received the sequence, it will exit Linking Mode
The ApplianceLinc Status LED will flash twice and then turn on solid
Removing the X10 Primary Address
If you are no longer going to control ApplianceLinc with an X10 Primary address, it is very important that
you Unlink it. Otherwise, ApplianceLinc will still respond to X10 commands and may cause ApplianceLinc
to turn on by itself.
1) Set ApplianceLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The ApplianceLinc Status LED will begin blinking
2) Set ApplianceLinc to Unlinking Mode by pressing & holding the Set button for 3 seconds
The ApplianceLinc Status LED will continue blinking
You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.
3) Using an X10 controller, send the X10 address you wish to remove and the ON command
three
times
For example, to remove the address A1, you would send “A1 ON A1 ON A1 ON”.
4) Once ApplianceLinc has received the sequence, it will exit Linking Mode
The ApplianceLinc Status LED will flash twice and then turn on solid