background image

ApplianceLinc Owner’s Manual  

 

Page 8 of 12 

 

X10 PROGRAMMING OPTIONS 

ApplianceLinc  is X10 ready, meaning that it can respond to X10 commands from X10 controllers. 
However,  to operate ApplianceLinc  in X10 mode, you must first set up an X10 Primary  Address. As it 
ships from the factory  or after a factory reset procedure, ApplianceLinc  will not have an  X10  Primary 
Address set up.

 

Setting the X10 Primary Address 

1)  Set ApplianceLinc to Linking Mode by pressing & holding the Set button for 3 seconds 

The ApplianceLinc Status LED will begin blinking 

 

You will have 4 minutes to complete the next step before Linking Mode automatically times out. 

2)  Using an X10 controller, send the X10 address you want to assign and the ON command 

three times

 

For example, to assign the address A1, you would send “A1 ON A1 ON A1 ON.”  

3)  Once ApplianceLinc has received the sequence, it will exit Linking Mode 

The ApplianceLinc Status LED will flash twice and then turn on solid  

Removing the X10 Primary Address 

If you are no longer going to control ApplianceLinc with an X10 Primary address, it is very important that 
you Unlink it. Otherwise, ApplianceLinc will still respond to X10 commands and may cause ApplianceLinc 
to turn on by itself.  

1)  Set ApplianceLinc to Linking Mode by pressing & holding the Set button for 3 seconds 

The ApplianceLinc Status LED will begin blinking  

2)  Set ApplianceLinc to Unlinking Mode by pressing & holding the Set button for 3 seconds  

The ApplianceLinc Status LED will continue blinking 

 

You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.  

3)  Using an X10 controller, send the X10 address you wish to remove and the ON command 

three 

times

 

For example, to remove the address A1, you would send “A1 ON A1 ON A1 ON”.  

4)  Once ApplianceLinc has received the sequence, it will exit Linking Mode  

The ApplianceLinc Status LED will flash twice and then turn on solid   

 

 

 

 

 

 

 

 

Содержание ApplianceLinc 2456S

Страница 1: ...ApplianceLinc INSTEON Plug In Appliance On Off Module 3 Pin Model 2456S ...

Страница 2: ... Load Sensing 7 Restoring Power to ApplianceLinc 7 Resetting ApplianceLinc to its Factory Default Settings 7 X10 PROGRAMMING OPTIONS 8 Setting the X10 Primary Address 8 Removing the X10 Primary Address 8 ADVANCED X10 PROGRAMMING OPTIONS 9 Remotely Setting an X10 Scene Address 9 Remotely Removing an X10 Scene Address 9 ABOUT INSTEON 10 Using Dual Band INSTEON Devices to Upgrade Your Network 10 Impo...

Страница 3: ...standard incandescent loads up to 480 Watts and inductive loads up to 15 Amps Indicates INSTEON setup mode activity and operational states with a Status LED Load Sensing easily disabled and re enabled Pass through outlet so you won t lose an outlet Responds to commands from X10 controllers Stores setup state in memory so settings aren t lost during power outages Two year warranty What is Included ...

Страница 4: ...terms refer to the components of an INSTEON scene and are used on a scene by scene basis Controller sends INSTEON commands to other devices Responder reacts to commands sent out by another INSTEON device An INSTEON device may act as a Controller Responder or sometimes both INSTEON networks are also extremely secure Each INSTEON device is assigned a unique INSTEON ID so unless neighbors or would be...

Страница 5: ...on the bottom of ApplianceLinc 2 Plug ApplianceLinc into an unswitched wall outlet The ApplianceLinc Status LED and the load will turn on 3 If the load does not turn on turn it on manually using the switch on the load itself 4 OPTIONAL You can use the pass through outlet on the front of ApplianceLinc as you would an ordinary uncontrolled wall outlet However do not plug another home automation prod...

Страница 6: ...going to discontinue using ApplianceLinc it is very important that you Unlink it from any Linked Controllers Otherwise the Controllers will retry any commands repetitively thus slowing down the system The following will work for the most common INSTEON devices 1 Set the Controller to Unlinking Mode For most Controllers press hold an On or Scene button for 10 seconds twice or the Set button for 3 s...

Страница 7: ...t button on ApplianceLinc for 3 seconds The ApplianceLinc Status LED will begin blinking 2 Double tap the Set button on ApplianceLinc The ApplianceLinc Status LED will stop blinking and turn on solid 3 Test that Load Sensing has been disabled by turning the load on and off from its built in switch The load will not respond Restoring Power to ApplianceLinc ApplianceLinc stores all of its settings s...

Страница 8: ...uence it will exit Linking Mode The ApplianceLinc Status LED will flash twice and then turn on solid Removing the X10 Primary Address If you are no longer going to control ApplianceLinc with an X10 Primary address it is very important that you Unlink it Otherwise ApplianceLinc will still respond to X10 commands and may cause ApplianceLinc to turn on by itself 1 Set ApplianceLinc to Linking Mode by...

Страница 9: ...HT commands after the X10 scene address is sent However they will ignore ALL ON and ALL OFF commands for the X10 scene address Remotely Setting an X10 Scene Address 1 Using an X10 controller send the CLEAR sequence O16 N16 M16 P16 M16 2 Use the Set button on ApplianceLinc to set the load to the desired state on or off 3 Send the following X10 address sequence M16 N16 O16 P16 4 Send the desired X10...

Страница 10: ...lly retransmit the command up to five times While using at least one dual band device is required when using an RF only device at least two dual band devices are recommended in any INSTEON network to ensure reliable communication across two phase home wiring systems For larger applications it is recommended to install at least one dual band device for every 750 1 000 square feet Search for dual ba...

Страница 11: ... If you are using home automation software you can easily check scene membership and eliminate unnecessary Links If the above doesn t work perform a factory reset on the Controller The load turned on by itself Another Controller a timer or stray X10 signals could have triggered ApplianceLinc Perform a factory reset See Resetting ApplianceLinc to its Factory Default Settings The Controller can turn...

Страница 12: ...rt Line at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to Smarthome Inc ATTN Receiving Dept 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fit...

Отзывы: