2475DA2 Rev. 7/24/2013 8:55 AM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see
www.insteon.com/patents
)
© Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022
1)
Write down the INSTEON ID found on the front of the unit
(XX.XX.XX)
2)
Turn off breaker/fuse and verify that the power is off
3)
Disconnect wires from existing switch
4)
Connect wires per diagram
5)
At the ballast location, disconnect the wires from the fixture
you will be controlling and ensure that you have ½ inch of
bare wire on the ends
6)
See the diagram to identify and connect the line, load,
neutral DC(+) and DC(-) wires on Ballast Dimmer. Be sure
you have correctly identified the wires in the junction box
before connecting them.
7)
After ensuring wires are firmly connected and that there is
no exposed wire, turn on breaker/fuse
After a few seconds, load will turn on
8)
Test Ballast Dimmer connection by tapping set button a
couple times
Ballast Dimmer
load will respond appropriately
9)
Link Ballast Dimmer to your INSTEON keypad or other
INSTEON controller. See Make Ballast Dimmer a
Responder
.
10)
Gently place Ballast Dimmer into the fixture box, making
sure nothing could accidentally press on the set button
11)
Reinstall the fixture
Quick Start Guide
Ballast Dimmer
INSTEON
®
Remote Control 0-10VDC Ballast Dimmer or Dual Switch
Model: 2475DA2 (US), 2446-422 (EU), 2446-522 (AUS/NZ)
About Ballast Dimmer
This in-line ballast control module supports two different operational modes: dimmer and dual-relay. For use in new construction
or retrofit (inside or outside the fixture) where saving energy is a priority.
RJ-10 Mini-modular jack pin-outs:
Pin 4
(Left side)
Pin 3
Pin 2
Pin 1
Group 1: triggers when switch between pin 3 & 4 is closed
Group 2: triggers when switch between pin 3 & 4 is opened
Group 3: triggers when switch between pin 2 & 4 is closed
Group 4: triggers when switch between pin 2 & 4 is opened
Ground
Group 1 - 2
Group 3-4
12-15VDC
Install Ballast Dimmer for Dimmable Ballast
Note: use with branch circuit breakers 15 Amperes or fewer.
Line (Black)
Neutral (White)
Set button
Status LED
Load 2 (Red)
Load 1 (Red/Black)
0-10VDC + (Purple)
DC ground (Grey)
The hot feeding this circuit is paralleled from the hot
connection on the keypad keeping both devices powered at
all times and using existing wiring.
RJ-10 jack
0-10VDC + (Purple)
DC ground (Grey)
Load 2 (Red)
Neutral (White)
Line (Black)