ERASE ALL:

 This function clears all keys from the 

memory. It will ask for confirmation by pressing “eco” 
button. Should you not wish to clear the keys, simply 
press the “On/Off” button as normal to exit the menu.      

Each DB2000 boiler can sync with 24 different keys, 
all with a unique combination. A key can be learnt by 
more than one machine to allow its use in multiple 
areas of the same building.    

NOTE:

 Additional “keys” are available from  

Instanta spares dept. (Tel: 01704 501114),  

Part No: DBKF021

 

Cleaning

The external surfaces of the machine can be kept 
clean by wiping with a damp cloth. A good quality 
stainless steel cleaner will keep the machine in its 
original condition. The plastic top trim may also be 
cleaned with a damp cloth. Do not use abrasive 
material on the outer surface of the machine.

 

Maintenance & Service

Information

The boiler should be periodically checked for scale 
build-up. The frequency depends upon hardness 
of the water and whether or not an effective scale 
reducer is fitted.

Apart from cleaning/de-scaling the level sensors and 
tank, no regular maintenance should be required.

DE-SCALING:

In hard water areas, the boiler should be descaled 
on a regular basis to maintain efficient operation, 
minimise energy consumption and also retain the 
water quality.  
 

Full de-scale of Tank & Probes:

•  Disconnect machine from power supply.

•  Empty the machine and allow to cool.

•  Remove outer-lid (spring-clips). 

•  Remove tank-lid (four/six fixing screws).

•  Lift out the evaporation plates (inside of tank –    
 

Remember order of removal).

•  Remove as much scale as possible by hand.  
 

Any scale which is difficult to remove can be  

 

dissolved by using a de-scaling solution.

 
 

•  Wipe clean the level sensing probes  
 

(using non-metallic scourer).

•  Flush with copious amounts of cold water to  

 

 

ensure all traces of de-scaler are removed before  

 

using the boiler again.  

•  Replace evaporation plates, tank-lid and  
 

outer lid. 

Clean & de-scale the Probes: 

•  Disconnect machine from power supply.

•  Remove outer-lid (spring-clips). 

•  Remove tank-lid (four/six fixing screws).

•  Lift out the evaporation plates (inside of tank –    
 

Remember order of removal).

•  Wipe clean the level sensing probes using a  
 

non-metallic scourer. It is important to clean  

 

the white insulators as well.

•  Replace evaporation plates, tank-lid and  
 

outer lid.

 

Service Warnings & Fault

Diagnostics

The DB2000 is fitted with an intelligent fault 
diagnosing system. There are two levels of diagnosis.

Simple warnings 

- accompanied by the  

 

illumination of a red exclamation mark.  

 

Your boiler will continue to operate as normal  

 

whilst displaying these warnings.

Critical faults

 - accompanied by the illumination  

 

of a red spanner.

6

Содержание CTSP15PB

Страница 1: ...The Professional s Choice CTSP15PB SureFlow Plus Touch Installation And User Instructions...

Страница 2: ...nd all relevant local and national standards including the following Health and Safety at Works Act IEE regulations Local and national building regulations BS Codes of practice Water supply regulation...

Страница 3: ...system Technical Information Outer casing and tank constructed in Type 304 stainless steel Internal baffle plates for condensing steam within the tank are made from Type 316 stainless steel The tank i...

Страница 4: ...sing the tapered rubber blanking bung provided Pipe work should then be provided between the rear overflow connection 1 2 bsp 15mm and a suitable waste drain NOTE Whichever overflow connection is chos...

Страница 5: ...g Lock Mode the optional key supplied must be synced to the machine as follows a Enter program mode as described above and scroll through menu until the display shows PROGRAM LEARN KEYS Hold for 3 sec...

Страница 6: ...nimise energy consumption and also retain the water quality Full de scale of Tank Probes Disconnect machine from power supply Empty the machine and allow to cool Remove outer lid spring clips Remove t...

Страница 7: ...ERMISTOR OC Temperature sensor has become disconnected or is faulty Contact supplier HEAT THERM FAIL Either the Over boil or Boil dry safety cut outs have activated Switch boiler off and back on after...

Страница 8: ...del Serial Number label on right hand side of machine This is essential Guarantee Your boiler is guaranteed for two years from date of installation Our guarantee includes on site labour and parts for...

Отзывы: