FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY
- 6 -
International Symbols
O
Power Off
I
Power On
Hot Surface
Risk of Electrical Shock
Protective Earth Terminal
Ground
Caution - Warning
Preventive Maintenance Suggestions
The IGS heat seal machines are relatively
maintenance free. For long, trouble-free life, the
following preventive maintenance should be
followed:
1. Do not heat seal items such as buttons,
pins, snaps, or zippers which tend to cut
the silicone rubber pad or scratch the
Teflon heat platen.
2. Periodically clean the Teflon-coated heat
platen with a non-abrasive piece of cloth.
Stubborn stains may be cleaned,
when
platen is cool
, with mineral spirits.
3. When the heat platen is hot and not in
use, keep in open position (away from the
silicone rubber pad).
4. To prevent soiling of substrate, periodic
wiping of the entire exterior machine,
including platens, with a clean rag is
recommended. If necessary, use mineral
spirits for cleaning a
cold
machine. Since
mineral spirits are flammable, use
precautions and keep away from sparks,
flame, or hot heat platen.
5. Occasionally apply a few drops of light
machine oil (such as
3-IN-ONE)
to
the
moving parts and pressure adjustment
screw.
NOTE
Wipe off any excess oil.