96
Ta
ble 8-44 Change User Settings Interface Instruction Table
Interface Parameters
Function Description
Default Value
User Name
Input the name of user to modify
----
User Password
Input the password of user to modify. Only both the name and
password are correct, the following options can be modified. ----
User
User privilege on-off settings. Options include:
Enabled
Disabled
Disabled
Change User Password
Change the user password. It must contain uppercase and
lowercase letters, special characters and numbers, within 8-20
characters.
----
Channel NO
Set BMC channel, input 1 or 8.
0
User Privilege Limit
Modify the user privilege. Options include:
Reserved
Callback
User
Operator
Administrator
Reserved
8.2.5.3 VLAN Configuration
VLAN Configuration interface is used to set the BMC VLAN parameters through BIOS.
Figure 8-70
Tab
le 8-45 VLAN Con
figuration Interface Instruction Table
Interface Parameters
Function Description
Default Value
Sharelink/Dedicated VLAN Control
BMC sharelink/dedicated VLAN control on-off settings.
Options include:
Enabled
Disabled
To enable VLAN, it needs to set the VLAN ID first.
Disabled
Sharelink/Dedicated VLAN ID
BMC sharelink/dedicated VLAN ID settings, the range is
2
~
4094.
The setting takes effect immediately.
0
Sharelink/Dedicated VLAN Priority
BMC sharelink/dedicated VLAN priority settings, the
range is 1
~
7.
The setting takes effect immediately.
0