6
Unit: km/h
0 = turn off limiter
Start up
Factory setting: 0
Speed display: P11, Distance display range: 0
– 1
0 = without assistance
1 = with assistance
Drive mode
Factory setting: 2
Speed display: P12, Distance display range: 0, 1, 2
0 = Automatic assistance determination
1 = Manual Assistance determination
2 = Both
Sensitivity
Factory setting: 1
Speed display: P13, Distance display range: 0
– 255
Boost start strength
Factory setting: 3
Speed display: P14, Distance display range: 0
– 5
0 = lower
5 = higher
Magnet type
Factory setting: 8
Speed display: P15, Distance display range: 5, 8, 12
5 = 5 magnetic plate
8 = 8 magnetic plate
12 = 12 magnetic plate
Current limit
Factory setting: 12 A
Speed display: P16, Distance display range: 0
– 255
Unit: A
Undervoltage protection
Factory setting: 31.0 V
Speed display: P17
Unit: V
For 24 V the range is 15.0
– 23.0
For 36 V the range is 20.0
– 35.0
For 48 V the range is 30.0
– 47.0
Auto cruise
Factory setting:
Speed display: P20, Distance display range: 1, 2, 3
0 = turn off
1 = turn on by pressing
„-„
2 = keep constant speed to turn on
Password settings
Factory setting: 0
Speed display: P22, Distance display range: 0, 1
If the value is 0, no password is required