Wiring Conversions
Table 1
NS1002
Neutral Live
CH
Comments
N
L1
L2
1
2
DANFOSS RANDALL FP975
N
L
5
6
If Terminals L,5 are
NOT
Linked
DANFOSS RANDALL FP975
N
L
Link Link 6
Only if Terminals L,5 are
Linked
DANFOSS RANDALL FP715Si
N
L
L
4
DANFOSS RANDALL 4033
7
6
L
2
HORSTMANN 425 DIADEM,
TIAGRA
N
L
5
4
If Terminals L,5 are
NOT
Linked
HORSTMANN 425 DIADEM,
TIAGRA
N
L
Link Link 4
If Terminals L,5 are Linked
HORSTMANN 425 CORONET
N
L
5
4
If Terminals L,5 are
NOT
Linked
HORSTMANN 425 CORONET
N
L
Link Link 4
If Terminals L,5 are Linked
HORSTMANN CHANNELPLUS XL
SERIES 2
N
L
5
4
If Terminals L,5 are
NOT
Linked
HORSTMANN CHANNELPLUS XL
SERIES 2
N
L
Link Link 4
If Terminals L,5 are Linked
HONEYWELL ST669
N
L
L
3
HONEYWELL ST6300, ST6400
N
L
L
4
HONEYWELL ST900A, ST900C
N
L
L
4
INVENSYS LIFESTYLE LP241,
LP522, LP722
N
L
L
4
POTTERTON EP2000, EP3000
N
L
L
4
RANDALL 702
N
L
L
1
SALUS EP200
N
L
L
4
SMITHS IND. CENTROLLER 1000 N
L
L
4
SWITCHMASTER 800, 805, 900,
9000, 9001
N
L
L
1
Where “Link” is specified, join terminals L2 and 1 together with a link wire.