background image

3.12 Image view

 

A clearer image may be observed from TV set via AV output since there is limit 

of pixels on the LCD screen (800×600). Similarly, the pixels of photo taken with the 
microscope may reach 2048×1536, and the image will clearer under photo playback 
mode or when observing photo from the computer after transmission. 

 

The maintenance of digital 

LCD microscope

 

For the sake of good microscope protection, it is required to avoid dust, water 

and humidity intruding into the instrument, otherwise, the photo route and the 
electronic circuit of microscope might be damaged. Moreover, the apparent grease 
spot, finger print on the surface of optical kit, dust, dirt stains will effect the imaging 
quality. 

When the microscope is not in use, the microscope should be covered with a 

clean sheath timely to prevent dust from entering in. 

The product is suitable for application and storage indoor, with the environmental 

humidity for operation and storage being 30%-80%. The environmental temperature 
for operation and storage being 0

- 40

 . 

 

Optical section

 

The lens should be stored in a dry environment, and it is available to place it 

in a container with drier agent. 

If the surface of lens is attached with dust, please use an air blower ball to 

clear it off. 

If the surface of lens is attached with finger print, dirt, greasy stain or other 

trace not available to use an air blower ball to clean, please use absorbent cotton 
or lens paper dipped with a little alcohol or ether mixture (proportion 1:4) to 
wipe off them lightly. 

Notice: Under no any circumstances should the lens surface be dry cleaned, 

otherwise the surface of lens may be damaged. Moreover, it is not allowed to 
wipe the lens with water or other liquid solutions.

 

LCD screen 

It is required to pay attention that no heavy pressure on the surface of color 

LCD screen is allowable during operation and storage. 

Содержание ISM-DLC120

Страница 1: ...OPERATION MANUAL ISM DLC120 LCD Microscope...

Страница 2: ...Manual The description of digital LCD microscope 2 The installation of digital LCD microscope 4 The Application of digital LCD microscope 5 The maintenance of digital LCD microscope 14...

Страница 3: ...isplay screen The buttons on the operation button layout may be increased or decreased as different function model 1 2 The description of digital LCD microscope The product is provided with an innovat...

Страница 4: ...nframe technical parameters Continual zooming ratio 1 6 5 0 7X 4 5X Total magnification 18 7X 120X 4 7X 240X can be obtained with varied accessories Digital amplification 8 4 inch TFT LCD display scre...

Страница 5: ...touch the surface of the optical parts and the surface of LCD screen directly with hand The image quality may be affected if the optical kits are stained with figure print or greasy stain As to the d...

Страница 6: ...The light source adopts LED ring lamp divided into the LED circular indicator with adjustable brightness and the multiple function LED circular indicator controllable at four zones The lower light sou...

Страница 7: ...e taken available at present or the video recording time with 143 indicating 143 photos available to be taken at the present setup mode 50 24 indicating the time for video recording at the present set...

Страница 8: ...may be used to select self definition graphics including the cross line coordinates lattice carrying out simple locating and measurement may be used to select among colors of the self definition graph...

Страница 9: ...th the micro ruler The standard ruler of every 12 graduations correspond to 19 graduations of the coordinate ruler then each graduation of the coordinate ruler is about 0 03mm 12 0 05 19 In this case...

Страница 10: ...osure time item exposure time can be set up between 1 5s 1 5s C Image Size Selection of different pixel may set up the photo size at single photo shooting mode D Date and time It is available to set u...

Страница 11: ...the image from 1 0X to 4 0X This digital zoom function can help user have a more clear view 3 9 Take photo and photo management Select single photo at the photo taken mode menu and press the photo ta...

Страница 12: ...connection line to transfer the data to the computer At the playback station with the help of the function menu it is available to carry out the setting as following A Delete the photos B Protect the...

Страница 13: ...the main system power supply 12VDC 3A SD MMC port is an interface to insert SD memory card Warning Before pull out the SD card please turn off the system USB port is used for the data communications...

Страница 14: ...are The screen show after connect the computer Open the software Impression 4 Choice the camera item select the Use computer to view the image format of the image to view the image For model ISM DLC12...

Страница 15: ...The product is suitable for application and storage indoor with the environmental humidity for operation and storage being 30 80 The environmental temperature for operation and storage being 0 40 Opt...

Страница 16: ...available to use clean and soft cloth to wipe lightly and it is forbidden to use organic solution agent to wash and clean It is forbidden for the consumers to disassemble the microscope by themselves...

Отзывы: