Attention

Don’t impact without measurement and calibration, otherwise the 
impact device may be damaged.

Please reading the operation manual careful before using, make 
sure  the  weight,  thickness,  surface  roughness  of  the  workpiece 
are meeting the requirement.

Please do calibration when use the device first time or interval for 
a long time.

Clean up the rusty, oil on the surface before measure.

The  distance  between  any  two  impact  position  should  be 

3mm.  the 

distance  between  impact  position  and  the  edge  of  the  sample  should 
be 

3mm.

Make  the  support  ring  stick  to 

  and 

keep the impact direction perpendicular to 

the  surface  of  the  workpiece

the surface.

Keep

workpiece  and  impact  device  steady  during   

measurement.

  operator, 

Structure:

Description

1

Impact device

Main unit

1. 
2. 
3. 
4. 
5. 
6. 
7. 

Impact body  
Support ring 
Coil    
Cable 
Catch chuck  
Loading tube
Release button

Working principle:

2

Push  down  the  loading  tube  before  measurement,  the  catch 
chuck catch up the impact body. Make the support ring stick to the 
surface  of  the  workpiece  and  keep  the  impact  direction 
perpendicular  to  the  surface. Then  press  the  release  button,  the 
impact  body  will  impact  the  surface.  The  coil  collect  the  velocity 
signal and the cable transmit the dada to the main unit.

LCD Display

Button