Insignia RW105 Скачать руководство пользователя страница 15

 

www.insigniashowers.com

 

Last Modified: 07/10/2021

 

 15 

Step 8 —

 

Connecting the power

 

The power box is located on the roof. Take all power cables from the 
panel heaters and the control panel and connect together.

 

Connect the control panel to 
the lights and speakers, located 
in the roof. Also take the 
thermostatic probe and place 
through the thermostatic probe 
holder, also located in the roof. 

 

Содержание RW105

Страница 1: ...chnical support for aiding your installation Replacements Parts Inside of your warranty period visit https www insigniashowers com click support and make a warranty claim Spares Replacements Parts Outside of your warranty period visit https www insigniashowers com replacement parts html CHECK ALL CONTENTS BEFORE BUILD COMMENCES NO RETURNS CAN BE MADE ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCE...

Страница 2: ... Tool requirements 4 Box contents 5 Back Panel to Base Install 6 Right Side Panel Install 7 Bench Heater Install 8 Bench Install 9 Left Side Panel Install 10 Door Install 11 Roof Install 12 Connecting the Electrics 13 Control Panel Instructions 14 Sauna Room Safety Guide 15 WEEE Compliance Statement 16 ...

Страница 3: ...d this booklet with great care to ensure you get the best out of your build and have a Sauna that will last for many years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish ...

Страница 4: ...h pre fitted RCD unit We leave it this way for you to connect it your own way due to continued additions to current regulations 1 Connect within current laws and IP directives Subject to room location 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Always use protection against electrical surge Your shower should be treated the same as a home compute...

Страница 5: ...1 35mm Screw 40mm Screw 50mm Screw Wooden Dowel 11 2 1 19 VERY IMPORTANT Have you got everything If not please contact the Insignia directly on 01908 317 512 Remember NEVER book your tradesman until everything has arrived been checked and is present No replacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours a...

Страница 6: ...www insigniashowers com Last Modified 07 10 2021 06 Step 1 Placing the base and the back panel in position ...

Страница 7: ...www insigniashowers com Last Modified 07 10 2021 07 Step 2 Connecting the back panel to the right side panel 3x 35mm Screws Please Note Screws connect on the interior of the Sauna ...

Страница 8: ...www insigniashowers com Last Modified 07 10 2021 08 Step 3 Installing bench heater Connect heater panel to back panel using the wires below Slide the bench heater between the two wooden struts ...

Страница 9: ...www insigniashowers com Last Modified 07 10 2021 09 Step 4 Installing the seat Slide the top of the seat into position resting on the wooden struts ...

Страница 10: ...www insigniashowers com Last Modified 07 10 2021 10 Step 5 Installing the left side panel 3x 35mm Screws Please Note Screws connect on the interior of the Sauna ...

Страница 11: ...www insigniashowers com Last Modified 07 10 2021 11 Step 6 Installing the door 4x 35mm Screws Please Note Screws connect on the interior of the Sauna ...

Страница 12: ...www insigniashowers com Last Modified 07 10 2021 12 Step 7 Installing the fixed glass panel Slide the Glass Panel into the grooves of the tray and side panel ...

Страница 13: ...www insigniashowers com Last Modified 07 10 2021 13 Step 8 Installing the corner post Slide the wooden corner post onto the fixed glass panel and slot it into the tray ...

Страница 14: ...wers com Last Modified 07 10 2021 14 Step 9 Installing the Roof The roof simply slots into position Now the Sauna is assembled take the wooden dowels and insert over any screw to give the Sauna a sleek and neat finish ...

Страница 15: ...ox is located on the roof Take all power cables from the panel heaters and the control panel and connect together Connect the control panel to the lights and speakers located in the roof Also take the thermostatic probe and place through the thermostatic probe holder also located in the roof ...

Страница 16: ...una Use this button to start the heaters for the sauna session Button 8 Audio function Use to toggle between radio Bluetooth and USB audio preferences Button 9 10 Mode Use to change the volume the music tack or radio station Button 11 Power Use to power the control panel on or off Radio Station Tuning Press the Memory button 5 for 3 seconds after the audio frequency flashes then press again to aut...

Страница 17: ...t have a heart condition have low or high blood pressure If you re unsure consult your GP before use 8 If you have any underlying health conditions which you feel could be aggravated by an increase in temperature consult your GP before use 9 If you begin to have any issues with your health after using a sauna stop immediately and consult your GP regarding your symptoms before continuing to use 10 ...

Страница 18: ...common crossed out wheelie bin label We accept returns of all products carrying the Insignia brand All other products are either considered outside the scope of WEEE or Insignia is not technically the producer of these products Insignia also accepts historic like for like WEEE returns All WEEE returned to Insignia will be recycled in appropriate treatment and recycling centres in accordance with t...

Страница 19: ...www insigniashowers com Last Modified 07 10 2021 19 ...