INSTALLATION INSTRUCTIONS
• Gap between the end of the water valve and the wall:
•
Case 1:
If you connect the supply hose
after
you install your washer: Over
3.9 in. (10 cm)
•
Case 2:
If you connect the supply hose
before
you install your washer: Over
2.8 in. (7 cm)
If you install your washer and dryer side-by-side in a closet, the closet front must
have an unobstructed air opening of at least 72 sq. in. (465 sq. cm).
Electrical requirements
Use a 120 Volt, 60 Hz, 15 amp fuse or circuit breaker. We recommend an individual
branch circuit that serves only your washer.
Electrical grounding is required for your washer.
• You must ground your washer. In the event of a malfunction or breakdown,
grounding reduces the risk of electric shock by providing a path of least
resistance for the electric current.
• Your washer has a power cord with a three-pronged grounding plug for use in
a correctly installed and grounded outlet.
• The outlet must be correctly installed and grounded in accordance with all
local codes and ordinances.
WARNING:
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT
SAFETY INSTRUCTIONS on page 3 before operating your washer.
WARNING:
Never use an extension cord.
27 in. (68.6 cm)
1 in. (2.5 cm)
1 in. (2.5 cm)
2 in. (5.1 cm)
29 in. (73.5 cm)
24 in. (61 cm)